OPERATION - NOTIFICATION SIGNS - TECHNICAL DATA
INSTRUMENT OPERATION
After connecting the power to the instrument, the display shows the following information for 2 seconds:
When X.YY is the current version of the software.
After 2 seconds the instrument displays the battery charge information.
Example:
setting for the display
of voltages V1, V2, V3
and of currents I1, I2, I3.
• If voltage and current are too high for the scale, 3 asterisks (***) will appear instead of numbers.
• If an interruption in the wiring occurs between a shunt and the corresponding input socket on the termi-
nal board M2, an entirely random value will be displayed as the relative current value.
NOTIFICATION SIGNS

TECHNICAL DATA

®
QUICK
RESERVES THE RIGHT TO MODIFY THE TECHNICAL CHARACTERISTICS OF THE EQUIPMENT AND THE CONTENTS OF THIS MANUAL WITHOUT PRIOR NOTICE.
RDS 1530 - REV003A
VOLTAGE
1530
FIELD
V1
V2
V3
I1
I2
I3
MODEL
INPUT CHARACTERISTICS
Supply voltage
(1)
Maximum absorption
(2)
AMBIENT CHARACTERISTICS
Operating temperature
GENERAL
Voltage measurement range
Current measurement range
Dimensions (W x H x D)
Weight
Classe EMC
(1)
The instrument can reset itself at a voltage less than 8 Vdc.
(2)
Typical value with backlighting on at high intensity.
(3)
At temperatures below 0°C the movement of the display crystals slows down.
DESCRIPTION
Charge voltage - battery 1
Charge voltage - battery 2
Charge voltage - battery 3
Charge current - battery 1
Charge current - battery 2
Charge current - battery 3
from 8 to 30 Vdc
from -20 to +70° C
(3)
from 0 to 30 Vdc
from 0.3 to 199.9 A
120 mm x 65 mm x 37.5 mm
EN 55022-B - FCC part 15 rules 47
GB
RDS 1530
100 mA
155 g
15