Wayne SWS Serie Manual De Instrucciones Y Lista De Piezas página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
(Continued)
TO PUMP
WELL
SEAL
WELL
CASING
Illustration A
TO
PUMP
PACKER
TYPE FOOT
VALVE
Illustration B
TO
PUMP
INCLINE
CHECK
VALVE
Illustration C
Figure 2
Pump Model
Shallow Well
protected against freezing.
Protect the pipe from damage from
swimmers and boats.
FOOT
VALVE
prevent the entrapment of swimmers.
SHALLOW WELL PUMP WITH
CONVENTIONAL STORAGE TANK
1. Install air volume control on tank.
2. Connect the copper tube from the air
volume control to the uppermost 1/8"
NPT opening on the side of pump. Be
sure the connections are tight. Leaking
can cause the pump not to prime.
3. Install a valve and an isolator hose
between the tank and the house
plumbing to aid in pump removal for
servicing and for reducing the noise
transmitted to the house through the
piping.
4. Provide a hose bib (faucet) at the
lowest point in the system to drain the
DRIVE
system for service or storage.
POINT
SHALLOW WELL PUMP WITH
PRECHARGED STORAGE TANK
1. Shut off the power to the pump.
2. Open the faucet nearest the tank and
allow all water to drain from the tank.
3. Measure the tank precharge at the valve
stem using a tire pressure gauge.
4. If necessary, precharge with an air
pump to 28 - 30 psi on 1/2, 3/4 and 1
HP pumps.
5. Slope the horizontal pipes upward
toward the pump to prevent trapping
air. If the horizontal distance exceeds
25 feet, see Chart 2 on page 3 for the
recommended pipe size.
DRIVE
POINT
Electrical
designed for indoor installation only.
The voltage of power supply must match
the voltage of the pump. The motors can be
converted to 115/230 volts by turning the
voltage selector to the desired voltage (See
Figure 6). Use a needle nose pliers to pull
the selector out approximately 1/4", rotate
and then reinsert in correct position.
Select the proper size wire and fuse (Chart
3). Time delay fuses are recommended
over standard fuses for motor circuit
protection. All pump motors have built-in
CHART 2 - PIPE SIZING
Pump
Opening
0-25
Inlet
1-1/4 in.
Install a screen
around the inlet pipe to
Risk of electrical
shock. This pump is
3
SWS Systems
Horizontal Distance
(Feet)
26-100
1-1/2 in.
PRIME
SUCTION
PLUG
Figure 3 - Horizontal Tank
AIR VOLUME CONTROL
HOSE
OUTLET
COUPLING
Figure 4 - Vertical Tank
DISCHARGE
28-30 PSI
1/2 HP, 3/4 HP
& 1 HP
Figure 5 - Precharged Storage Tank
www.waynepumps.com
100-300
2 in.
AIR VOLUME
CONTROL
TUBING
AIR
VOLUME
AIR VOLUME
PRIMING
PLUG
NOZZLE
CLEAN
OUT
DRAIN
FITTING

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sws50-1/2 hpSws75-3/4 hpSws100-1 hp

Tabla de contenido