EdilKamin BIG Manual De Instalación, Uso Y Mantenimiento página 18

Ocultar thumbs Ver también para BIG:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
All local and national laws and European standards must be
met when installing and using the appliance. In Italy, refer to
the UNI 10683/2012 standard, as well as any regional or local
health authority regulations
It is necessary to refer to regulations in force in each country. If
installing in an apartment building, check with the management
VERIFY COMPATIBILITY WITH OTHER
DEVICES
The stove MUST NOT be installed in the same space as type B
gas heating equipment (e.g. gas boilers, stoves, and equipment
served by an extraction hood) as the stove may cause a vacuum
units work.
FIRE PREVENTION SAFETY DISTANCES
The stove must be installed in compliance with the following
safety conditions:
cm from the sides and back of the stove
cm if placed in front of the stove.
If it is not possible to comply with the above mentioned
distances, technical and construction-related provisions
must be appropriately insulated
AIR INTAKE
The room of installation must have a suitable outside air intake
with a through surface area of at least 200 cm
to replenish the burnt oxygen and ensure an adequate combu-
FIRE DAMPERS
be distinguished from the outside through the adjustment knob.
be able to close automatically.
but it must guarantee a permanent minimum opening which
should be equal to 3 % of the section itself and in any case
equal to at least 20 cm
.
2
CONVEYING ADJUSTMENT
"Two pipe unions are located on the back of the stoves for hot
air channelling.
Each pipe union can be used to send hot air to an adjacent room
using one KIT 8 per outlet, or both can be used to send air to the
same adjacent room using one KIT 9 (use of a single air grate
for the emission of air into the room)."
"To manage the supply of heating air using the two rear pipe
unions (see Page 14) use:
- Lever control B for the RH union
- Lever control A for the LH union."
N.B. A and B lever controls must only be operated using the
thermal glove supplied as they can heat up considerably.
Various alternatives exist for the distribution of heating air.
INSTALLATION
(Ø 16), in order
2
- 18
-
A
B
0%
front grille
A
B
50% right
front panel
A
B
50%
Left front panel
A
B
100%
front grille

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

LuxGlamVip

Tabla de contenido