Technical Data
Plasma cutter
Art. No
U
Rated input voltage AC Current
1
U
Idle voltage
0
I
/ U
Performance range (Welding current / Operating voltage)
2
2
X
Switch-on time
Actual working time and total working time ratio.
Switch-on time determined at 40°C using simulation
I
Maximum rated input current
1max
I
Maximum effective input current
1eff
Type of protection
IP21S
Insulation class
Class H
Compressed air (Flow rate, Pressure)
Material thickness max.
Weight
Class A (IEC 60974-10):
If you intend to use the apparatus in residential sur-
roundings supplied by the low voltage mains supply,
an electromagnetic filter may be required to suppress
electrical disturbance to a level where they will no
longer be a nuisance to the user.
The apparatus may be used in industrial or other
areas where power is not supplied by municipal LV
mains.
Class A apparatus are not intended for use in resi-
dential areas where power is supplied via municipal
LV mains, since unfavourable power conditions may
cause interference.
As a user, you must make sure, after consultation with
your energy provider, if necessary, that your point of
connection on which the machine is to be operated
meets the requirements above.
The user is responsible for faults arising from the
welding.
Read and understand the operating
instructions before using the appliance. Familiari-
se with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties.
Persons over 18 years of age can only work on the
appliance. An exception includes youngsters trained
in order to reach knowledge under supervision of the
trainer during occupational education.
The operator is responsible for accidents or risks to
third parties.
I
= 40 A / U
= 96 V
2
2
I
= 23A / U
= 89 V
2
2
I
= 17,9 A / U
=87,1 V
2
2
In case of any doubts about connection and operati-
on refer please to our customer center.
Safety Instructions
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
Persons with life support devices such as pacemakers
should consult their doctor before approaching this
apparatus, to ensure that magnetic fields and high
electrical currents will not interfere with such devices.
Operation is only allowed with a safety
switch against stray current (RCD max. stray
current of 30mA).
Before putting into operation, a qualified electrician
must check whether electric safety measures required
are in place. Any national regulations in this regard
must be complied with.
Electric connection to a socket.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Insert the plug of the electrical cable in a socket of
suitable shape, voltage and frequency complying
with current regulations.
Protect the circuit with slow-acting fuses of an appro-
priate size and a mains breaker switch.
Protect the feeder cable from excessive temperatures,
oil and sharp edges.
Use extension cables with a maximum length of 5
meters and with a cable cross-section of not less than
ENGLISH
GPS-E 40 A
20086
230 V
270 V
15 A/86 V - 40A/96V
20 %
60 %
100 %
25,2 A
11,3 A
IP 21S
H
min. 150 l / min
3-6 bar
10 mm
6,7 kg
15