alarm system. A0~A7 are address code which should be the same with that of the networking alarm system. D0~D3
are data code, used to set defense zones.
Usage
1) Inserting the ready battery into the battery cabinet and keeping the battery power supply,
2) Connecting the AC power wires (for AC TYPE), the detector will enter into normal working status. The indicator
flashes once per 45 seconds.
Sensitivity Test
The detector should be tested periodically to assure normal operation. Once per month is recommended. Press and
hold the TEST & HUSH BUTTON for more than 1s to make the detector enter into testing status. If the alarm indicator
flashes rapidly and the buzzer gives out alarm sound, then the detector works properly.
Alarm & Hush Function
When smoke density in surroundings reaches the alarm threshold of the detector, the buzzer gives out alarm sound
and the alarm indicator flashes rapidly. At this time, pressing the TEST & HUSH BUTTON will make the detector enter
into mute status that lasts for 10 minutes. During this period, the indicator flashes once per 10s and if the density is
still higher than the thr e shold, the TEST & HUSH BUTTON is nonfunctional. When the smoke density goes below the
threshold, pressing the TEST & HUSH BUTTON will activate the detector to perform testing operation. After the 10
minutes, the detector recovers automatically to normal working status.
Networking to Alarm System
Press the TEST & HUSH BUTTON and the detector will send out alarm signal. If use learning code alarm systems, under
learning mode, users can program the detector into the alarm system by pressing the TEST & HUSH BUTTON. When an
alarm occurs, users can see the alarm information from the system and take corresponding countermeasures to
reduce losses.
Malfunction Check
When the detector buzzer gives out a Di sound every 40 seconds along with the alarm indicator flashing once, the
battery voltage should become lower than the detector's normal operating voltage. At this time, replace the battery
with a new one. Otherwise, it will influence the detector' normal operation. If the buzzer gives out 2 Di sounds every
40 seconds along with the alarm indicator flashing twice, the infrared photoelectronic sensor should have a
malfunction. Pls contact with the dealer in time. Do not attempt to remove and repair the detector personally to
prevent incidents.
JUMPER SETTING SKETCH
NOTE
1. Perform the SENSITIVITY TEST as requested.
2. Clean the detector surface with soft bristled brush
every 6 months to assure the detecting sensitivity.
Remember to cut off the power source before
cleaning.
3. If the detector is not used for a long time, remove
the detector, take out the battery from the cabinet
and store it in a cool and dry place.
4. The detector can reduce the happening rate of
disasters. But it can not guarantee a hundred percent
safe. For safety consideration, pls use the detector
properly and heighten vigilance and safety
consciousness to take preventive measures.
Directive 2002/96/EC
Correct Disposal of this product:
This marking indicates that this product should not be disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources.
To return your used device, please use the return and collection systems or contact the retailer where the product
was purchased. They can take this product for environmental safe recycling.

Publicidad

Tabla de contenido
loading

Tabla de contenido