DESCRIPTION
Sirio is an electronic device, employing inverter-based technology, which controls motor pump stopping
and starting functions.
Thanks to the particular type of techno l o g y u s e d , i t c a n m o d u l a t e t h e f r e q u e n c y ( H z ) o f t h e m o t o r ' s i n p u t
current to alter the speed (rpm) according to the water delivery rate required from the system.
This way, the value of the pressure reaching the user appliances is maintained constant all the time and
the motor's absorption is always proportional to the actual system requirements, resulting in notable
energy savings over time.
SPECIFICATIONS
P o w e r m a i n s s u p p l y : ......................... .single-phase, 230Vac ±10% - 50/60Hz
Mo t o r p o w e r s u p p l y : ...........................three-phase 220V~
Ma x i m u m p o w e r a b s o r p t i o n : ..................2 2 0 0 W – 3Hp
Ma x i m u m m o t o r p h a s e c u r r e n t : ...............9 . 7 A r m s
Ma x . l i n e a b s o r p t i o n : ...................... ......1 6 A @ 2 3 0 V ~
Ma x . a l l o w a b l e p r e s s u r e : ................ .... . . . . . 8 0 0 K P a ( 8 b a r )
Ma x . l i q u i d t e m p e r a t u r e : ................... . . . . 50°C
Max. theoretica l f l o w r a t e : .....................1 5 0 l / m i n – 9m
/h – 9000 l/h
3
Set-p o i n t a d j u s t m e n t r a n g e : ................... . 1 . 5 ÷ 7 b a r
S t a r t p r e s s u r e a d j u s t m e n t r a n g e : ...............1 ÷ 6 . 7 b a r
H y d r a u l i c c o n n e c t i o n ...........................1 " ¼ m a l e -male
F r e q u e n c y m o d u l a t i o n r a n g e : ................ ...2 5 ÷ 5 0 H z ( 3 0 -60Hz optional)
Degre e o f p r o t e c t i o n : ..................... .... . I P X5
We i g h t .............................................1 . 6 K g
D i m e n s i o n s ........................................ 2 5 4 x 1 4 7 x 1 4 3 m m
Type of action..................................... 1 ( a c c o r d i n g t o E N 6 0 7 3 0 -1)
FEATURES
Constant pressure due to motor pump speed regulation
Energy savings due to less pump absorption
Gradual pump start and stop reduces hammering
Protection against dry running in the event of water shortage during intake
Automatic reset in the event of dry running, with autonomous error condition recovery
Efficient leakage monitoring to protect pump in the event of repeated restarts
Digital pressure display
Operation/error status signalling via LEDs and on-screen alerts
Auxiliary contact for remote control, pair connection or double set-point
Rotation direction inversion via software (does not require wiring alterations)
Extractable terminals to facilitate wiring
Possibility of interfacing two devices as part of the pressurisation units