INSTALLATION INSTRUCTIONS - FREESTANDING GAS RANGE
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Clearances and Dimensions
1. Provide adequate clearances between the range and adjacent combustible surfaces.
2. Location—Check location where the range will be installed. Check for proper electrical supply, and the stability
of the floor.
3. Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must
be solid and level.
FRONT
VIEW
Minimum to wall
(76 cm)
on either side of
Minimum
range above
counter / cooktop. 6"
(15.2 cm)
36"
(92 cm)
All dimensions for electrical outlet location
shows where the electrical outlet must be
for flush to the wall installation.
24"
(61 cm)
10"
(25 cm)
3-3/4" (9.5 cm)
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE BOTTOM OF AN UNPROTECTED
WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT
LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015"
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR
THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE,
POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE
LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN
BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE
BOTTOM OF THE CABINETS.
24"
(61 cm)
30"
Minimum to
cabinets on
18"
either side of
(46 cm)
range.
24"
0" (0 mm) clearance at sides and rear of range.
(61 cm)
are maximum.
Shaded area
installed
Wall
Edge
SIDE
VIEW
L
13"
A
33 cm
R
Maximum depth
W
for cabinets
O
I N
above range top.
B
25"
A
64 cm
C
35"
35"
89 cm
89 cm
4
L
T
10"
Open space
E
for gas
This space
must
remain clear
9"
2"
12"
Gas location
24"
23.5"
23-5/8"
60 cm
60 cm
W
A
C
L L
O
A
R
B
I N
11"
E
T
41.5"
105 cm
Maximum
door open