Idiomas disponibles

ADAPTING BLOWER FOR
C3.
RECIRCULATION
Place the blower unit back into the opening.
5
CAUTION:
blower unit wiring. Make sure the wires are not
pinched.
6
Replace blower plate and replace screws for blower
plate and blower motor removed in Step 1.
Blower Plate Screws
C4.

MOUNT THE OVEN

FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE
RECOMMEND THAT TWO PEOPLE INSTALL THIS OVEN.
IMPORTANT: Do not grip or use handle during
installation.
NOTE: If your cabinet is metal, use the nylon
grommet around the power cord hole to prevent cutting
of the cord.
NOTE: We recommend using filler blocks if the
cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are not used, case
damage may occur from over tightening
screws.
Installation Instructions
(continued)
Do not pull or stretch the
Blower Plate
Back of
Oven
Blower Motor Screw
NOTE: When mounting the
oven, thread power cord
through hole in bottom of
top cabinet. Keep it tight
throughout Steps 1–3. Do
not pinch cord or lift oven
by pulling cord.
2 Rotate front of oven up
against cabinet
bottom.
Cabinet Front
Cabinet Bottom Shelf
21
1
Lift oven, tilt it
forward and hook
slots at back bottom
edge onto two lower
tabs of mounting plate.
Filler Block
Equivalent to Depth
of Cabinet Recess
Self-Aligning Screw