A4.
ADAPTING BLOWER FOR
OUTSIDE VENTILATION
(Cont.)
7
CAUTION
sure the wires are not pinched.
Close the blower door. Secure the blower to the
microwave using the screws from Step 1.
8
CHECK FOR PROPER
A5.
DAMPER OPERATION
top of the unit facing up.
• Make sure tape securing damper is removed and
damper pivots easily before mounting microwave.
• Slide the damper into place. Make sure it catches
in the retaining hooks to secure.
• You will need to make adjustments to assure proper
microwave is installed.
14
Installation Instructions
Do not pull or stretch the
blower unit wiring. Make
Damper
Exhaust Adaptor
Back of
Microwave
Oven
A6.
MOUNT THE MICROWAVE
OVEN
FOR EASIER INSTALLATION
CAUTION
AND PERSONAL SAFETY,
WE RECOMMEND THAT TWO
PEOPLE INSTALL THIS MICROWAVE OVEN.
IMPORTANT: Do not grip or use handle
during installation.
NOTE:
grommet around the power cord hole to prevent
cutting of the cord.
NOTE: We recommend using filler blocks if the
cabinet front hangs below the cabinet bottom shelf.
IMPORTANT: If filler blocks are not
used, case damage may occur from
overtightening screws.
NOTE: When mounting
the microwave oven,
thread power cord
through hole in bottom of
top cabinet. Keep it tight
throughout Steps 1–3. Do
not pinch cord or lift oven
2 Rotate front of oven
up against cabinet
bottom.
Insert a self-aligning screw through top center
3
turning the screw at least two full turns after
Be sure to keep power cord
tight. Be careful not to pinch the cord,
especially when mounting flush to bottom of
cabinet.
1
forward, and hook
slots at back bottom
edge onto four lower
tabs of mounting
plate.

Publicidad