Remedy Of Faults - Oase PondoVac 4 Instrucciones De Uso

Ocultar thumbs Ver también para PondoVac 4:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Abnormalities
Unusual behaviour could be encountered during operation.
The unit heavily vibrates. Turn the unit off at the power switch (16) and on again after 20 seconds. If vibration per-
sists, probably either
− the tank is full (when operated as a wet vacuum cleaner, plug inserted),
− or the intake distributor, the drain or the foam filter is soiled.
In this case, clean and service the unit.
Vapour develops. No reason to worry. This is condensate released through the ventilation slots in the form of water
vapour. This effect is particularly encountered in cold weather.

Remedy of faults

Malfunction
Vapour escapes from the unit
The unit develops noise and/or heavy vibration
The unit does not suck or its performance
reduces
Low suction capacity
The container does not empty
Poor unit switching behaviour between the
containers, or no switch-over
Questions, problems, missing parts?
Before returning to your retailer, call us at 1-866-627-3435, 8 a.m.-6 p.m., EST, Monday-Friday, or email us at
customercare@oase-livingwater.com. Or visit our website at www.oase-livingwater.com
Cause
In cold weather, condensate forms in the unit,
which is released in the form of water vapour.
The tank is full
Intake distributor, drain or foam filter is soiled
No mains voltage
Excessive height difference between water
level and unit
Both containers are full of water. The float
bodies seal completely
Dirt plugs foam filters, the suction tube or the
suction hose
The flap at the intake distributor is jammed or
soiled
O ring at the inlet distributor not properly seated
The flap at the outlet valve is jammed or soiled
O ring at the distributor unit not properly seated
O ring at the inner tank not properly seated
Increased tube friction resistance
Suction depth too large. Due to the design, the
suction capacity reduces as from a suction
depth of 6.5 ft (2 m)
The drain hose is kinked or was not laid with an
incline
Drain hose or drain valve plugged with dirt
Dirt film on the pistons after an extended down
time
-
English
Remedy
This is normal. No remedy necessary
Drain tank
Switch off the unit, wait 20 s, then switch on
again. If the malfunction reoccurs, clean the
unit.
Check mains voltage
We recommend that the outlet height is slightly
above the water level
Drain the unit
Remove dirt
Remove the intake distributor. Check the flap
seating (Fig. H, 25)
Check the O-ring seating (Fig. H, 25)
Remove the drain hose. Check the flap seating
Check the O-ring seating (Fig. I, 28)
Check the O-ring seating (Fig. I, 27)
Keep the suction hose as short and flat as
possible.
Reduce the suction depth
Route the hose correctly. See Installation.
Remove dirt from the drain hose and the drain
valve
Remove motor housing (G, 17). Start the
switching cycle manually by holding the motor
head overhead.
-
7

Publicidad

Tabla de contenido
loading

Tabla de contenido