Abus FURM35000A Manual De Instrucciones página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 179
Scope of delivery | Technical data
Functional principle and features
The smoke alarm device does not detect gas, steam, fire or flames.
People with impaired hearing may not be able to hear the alarm.
Alarms with additional optical signalling are available for such cases.
Particularly high electromagnetic radiation could impair the function
of the detector. For this reason, do not install the detector near
magnets or devices which produce electromagnetic radiation.
The smoke alarm device operates in accordance with the optical
principle (photoelectric reflection) and features a measurement
chamber in which infiltrating smoke particles are measured.
If the alarm threshold is exceeded, a loud acoustic alarm sounds.
The smoke alarm device also has a heat detector that triggers an
alarm if a threshold value is exceeded.
The alarm is switched off as soon as the measurement chamber is
free of smoke again and/or the temperature has fallen back to a
normal level.