SKYLOTEC SIRIUS Instrucciones De Uso página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 43
Tested and approved for descents with a released
energy of 7.5 MJ (according to EN 341 class A):
W = m ∙ g ∙ h ∙ n
W = energy [J]
m = mass [kg]
g = acceleration of gravity= 9,81m/s2
h = height [m]
n = number of descents
EN 12841:2006 Type C
Tested for use with low stretch ropes (EN 1891 type A)
with diameter 10 mm ≤ ø ≤ 12 mm
Maximum working load: 250 kg.
ANSI/ASSE Z359.4-2013
Refer to ANSI Z359.1 and ANSI Z359.4 standards and
any applicable regulations.
Single-person use: (130 lb to 310 lb, 59 kg to 141 kg);
Maximum descent distance: 620 ft = 190 m;
Maximum descent rate: 6.6 ft/s ≈ 2 m/s;
Maximum number of descents: 25;
Rope: Skylotec Superstatic, 11 mm low-stretch rope.
Tested and approved for multiple descents with a
released energy of 5 500 000 foot-pounds. The descent
energy rating is determined by:
E = W x H x N
E = energy [foot-pounds]
W: test weight [lb]
H: descent height [ft]
N: number of descents
11

Publicidad

Tabla de contenido
loading

Tabla de contenido