The socket (female) insert of the connector must be
the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or
electrical device. On 50Hz units, the pin (male) insert
of the connector is installed at the factory. To ensure
effi cient sealing, use only smooth circular cable.
Pin Insert (Installed on Stub Cord)
Main Body
Pin Insert
Socket Insert (User Installed)
Socket insert
Main Body
Note:
White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.
Assembly/Wiring Instructions
STEP ONE
Remove the socket insert from the housing of the con-
nector. There is a slot for a fl at blade screwdriver in
the center of the insert.
Note: The inserts have a LEFT HAND
THREAD and should be turned clockwise to remove.
STEP TWO
Remove the gland nut and gland from the rear of the
housing and slide on to the cable. Make sure the gland
is orientated with the stepped edge facing the gland
nut (see picture).
Gland
Gland Nut
Gland
Gland Nut
Stepped Edge
STEP THREE
Prepare the cable and strip wire ends as shown.
Wire Stripping
Wire Stripping
STEP FOUR
Insert the stripped wire ends into the terminals on the
back of the Pin/Socket insert and fully tighten the
wire retention screws. (Refer to fi gure for correct wire
orientation).
Single phase wiring:
3 phase wiring:
After the wires have been connected securely, pull the
cable and insert back into the housing and tighten with
a screwdriver to ensure the insert is seated correctly.
Note: LEFT HAND THREAD, turn the insert
counter clockwise to tighten.
Figure 5:
Wire Connections
Brown wire to terminal L
Blue wire to terminal N
Green/Yellow wire to terminal E
Figure 6:
Wire Connections
Brown wire to terminal 1
Black wire to terminal 2
Grey wire to terminal 3
Green/Yellow wire to terminal E