Westinghouse 63718 Manual De Instrucciones página 18

Tabla de contenido

Publicidad

FIGURE 1.
E
C
MOUNTING AND WIRING INSTRUCTIONS
GB
NOTE: Line art shown may not exactly match the fixture enclosed. However, the installation
instructions do apply to this fixture.
The light source of this luminaire is not replaceable; when the light source reaches its end
of life the whole luminaire shall be replaced.
1. Turn off power at circuit box to avoid possible electric shock.
2. Remove retaining screws (B) from face plate (A) and separate mounting plate (C) from face
plate (A).
3. Position flat side of mounting plate (C) against wall at mounting location and mark outer
holes (D) with a pencil.
NOTE: Mounting plate (C) must be level for fixture to hang straight.
4. Drill a 1/8 inch hole at each pencil mark then insert wall anchors (E) by gently tapping with a
hammer.
5. Position mounting plate (C) with outer holes (D) over wall anchors (E) and secure with screws (K).
6. Make an electrical connection by loosening the terminal screws on the terminal block (M)
and inserting the live, neutral and ground terminals.
7. Tighten terminal screws. Make sure there are no stray wires.
8. Replace face plate (A) over mounting plate (C) and secure with retaining screws (B).
9. Secure the glass panel(s (F) by cap nuts (G) and washer(s) (H) .
10. Turn power back on at circuit box.
18
D
K
A
M
G
H
B
F
GS-26-RS14-WH19

Publicidad

Tabla de contenido
loading

Tabla de contenido