STOPPING THE ENGINE
See Figures 10 - 11.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Turn the fuel valve to the OFF (O) position.
To stop the engine, put the engine switch in the OFF (O)
position.
To stop the engine in an emergency situation:
Put the engine switch in the OFF (O) position.
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts can create a hazard or cause
product damage.
WARNING:
Before inspecting, cleaning, or servicing the machine,
shut off engine, wait for all moving parts to stop, and
disconnect spark plug wire and move it away from spark
plug. Allow 30 minutes of cool down time before perform-
ing any maintenance. Failure to follow these instructions
can result in serious personal injury or property damage.
WARNING:
Periodically inspect the entire product for damaged,
missing, or loose parts such as screws, nuts, bolts, caps,
etc. Tighten securely all fasteners and caps and do not
operate this product until all missing or damaged parts
are replaced. Please call 1-920-756-4688 or contact an
authorized service center for assistance.
GENERAL MAINTENANCE
Keep the generator in a clean and dry environment where it
is not exposed to dust, dirt, moisture, or corrosive vapors.
Do not allow the cooling air slots in the generator to become
clogged with foreign material such as leaves, etc.
Do not use a garden hose to clean the generator. Water
entering the fuel system or other internal parts of the unit can
cause problems that will decrease the life of the generator.
OPERATION
While operating and storing, keep at least 3 feet of clear-
ance on all sides of this product, including overhead.
Allow a minimum of 30 minutes of "cool down" time
before storage. Heat created by muffler and exhaust
gases could be hot enough to cause serious burns and/
or ignite combustible objects.
HIGH ALTITUDE OPERATION
Specific modifications are needed for high-altitude operation.
Please contact your authorized service center for important
information regarding these modifications. Operating this
engine without the proper altitude modification may increase
the engine's emissions and decrease fuel economy and
performance.
MAINTENANCE
To clean the unit:
Use a soft bristle brush and/or vacuum cleaner to loosen
and remove dirt and debris.
Clean air vents with low pressure air that does not exceed
25 psi.
Wipe the exterior surfaces of the generator with a damp
cloth.
SPARK ARRESTOR
See Figure 14.
NOTICE:
This product is equipped with a spark arrestor that has
been evaluated by the USDA Forest Service; however,
product users must comply with Federal, State, and lo-
cal fire prevention regulations. Check with appropriate
authorities. Contact customer service to purchase a
replacement spark arrestor.
Inspect the spark arrestor for breaks or holes. Replace if
necessary.
Use a brush to remove carbon deposits from the spark
arrestor screen as needed.
CHANGING FUSE
See Figure 15.
The generator contains a 2 Amp fuse to protect the battery
charge circuit from short circuit. To replace the fuse:
NOTICE:
Do not use a higher rated fuse other than the specified
amperage. This could cause damage to the product.
15 — English
WARNING: