Adjusting Air Pressure; Tool Operation - Porta-Nails 472A Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TESTING THE TOOL
(continued)
3) Remove the finger from the trigger and contact the ram cap.
• The tool must not operate.
4) First, pull the safety trigger. Next, contact the ram cap.
• The tool must operate.

ADJUSTING AIR PRESSURE

WARNING
Adjust the air pressure at recommended operating pressure 70 – 100 psi according to the length of
fasteners and the hardness of workpiece . The correct air pressure is the lowest pressure which will do the
job . Using the tool at a higher than required air pressure unnecessarily over stresses the tool .
LOADING FASTENERS
WARNING
• When loading fasteners into the tool,
1 . Do not contact the ram cap
2 . Do not depress the safety trigger; and
3 . Keep the tool pointed downward
TO PREVENT ACCIDENTAL INJURIES:
Never place a hand or any other part of the body in tool discharge area of tool while the air supply is
connected.
Never point the tool at anyone else.
Never engage in horseplay.
Never pull the trigger unless nose is directed at the work.
Always handle the tool with care.
Do not pull the trigger or depress the trip mechanism while loading the tool.
• Do not exceed 100 psi
(6.2 bar 6.3 kgf/cm
14
LOADING FASTENERS
)
2

TOOL OPERATION

Read section titled "SAFETY" (pages 4-7)
• Operators and others in work area MUST wear safety glasses
with side shields which conforms to ANSI Z87.1 specification.
• NEVER point tool at yourself or others in work area.
• Keep fingers AWAY from trigger when not driving fasteners to avoid
accidental operation.
• Never place your face, hands or feet closer than 8 inches (200 mm) from discharge area when
using. The tool may bounce from the recoil of driving a fastener and an unwanted second fastener
may be driven possibly causing injury.
• Check operation of the safety mechanism frequently. Do not use the tool if the safety is not
working correctly as accidental driving of a fastener may result. Do not interfere with the proper
operation of the safety mechanism.
• The safety trigger is a safety device and should only be pulled when the tool is in proper position
on the work surface and before the ram/actuator is struck with the mallet.
• Do not tie or tape down the safety trigger as the tool could discharge if dropped on the plunger. The
tool will not operate unless the trigger is pulled before striking the ram/actuator with the mallet.
• Do not use the safety as a disabling mechanism for the ram/actuator in order to use the tool to
rack the wood. This will severely damage the mechanism and the tool. This abuse and damage is
not covered by the warranty. Use the mallet to rack the flooring, not the tool.
• Do not strike the ram/actuator without pulling the safety trigger! Hitting the tool with the safety
engaged will damage the safety mechanism and the tool.
(continued)
Insert 15-1/2 Ga 1/2" Crown Staples in the top of the
magazine as shown . Engage pusher assembly . The tool is
now ready to operate .
DANGER
WARNING
15

Publicidad

Tabla de contenido
loading

Productos relacionados para Porta-Nails 472A

Tabla de contenido