Replacement Parts

Charts (60/pack)
ET6 Ranges
0 to +100
0 to +200
0 to +300
-10 to +10
-50 to +50
0 to 14
-20 to +120
NOTE: (ET6-2pen only) Chart number C669 has the following 2 ranges imprinted on it
so you can record both pH and temperature simultaneously: 0-14 and (-20) to 120
Accessories/Probes
Pens (6 red)
Pens (3 red & 3 blue)
Software and cable
3-Pt. NIST traceable certificate of calibration
One year extended warranty

Troubleshooting

Symptom
Pen trace too
fine or absent.
Readings of pen and
display do not
match exactly.
Und
Out of calibration
or
Questionable accuracy
Ovr
Prb
Factory Service and Returns
We recommend that damaged instruments be
returned to our factory for complete repair. Before
returning any instrument or package, please call for
a Return Authorization (RA) number.
When calling, please have the following information
available:
1.
P.O. number for out-of-warranty units.
2.
Serial number of unit.
The Dickson Warranty
Dickson warrants the ET6 line of instruments will be
free from defects in material and workmanship or
accidental damage for a period of twelve months
after delivery. In the event of a claim under this
warranty, the product or part must be returned
to the factory for repair or replacement (shipping
prepaid) with a Return Authorization Number (See
repair information above). It will be repaired or
replaced at Dickson's option without charge.
This warranty does not cover routine calibration,
pen, chart and battery replacement.
Dickson manufactures a complete line of temperature, humidity, air quality &
pressure instruments. Send or call for a free catalog of Dickson products.
24-hour Chart
C658
C672
C674
C676
C652
C668
C668
Cause
Tip too sharp, cartridge
dried out.
Wrong Chart
Pen not on properly
Line thickness
Below range of recorder
Harsh environments,
stressful conditions,
or time.
Above range of recorder
Sensor missing
3.
4.
Clearly mark the RA number on the outside
of the package and return the instrument,
shipping prepaid. Delivery will be refused for
packages sent without RA numbers.
The foregoing warranty and remedy are exclusive
and in lieu of all other warranties either expressed
or implied. Dickson shall not be liable for conse-
quential or incidental damages resulting from failure
or malfunction of its products. Dickson makes no
warranty for products not manufactured by it or
for any products modified by buyer, or subject to
misuse or neglect.
8
7-day Chart
C657
C671
C673
C675
C651
C669
C669
Check/Remedy
Sand tip, moisten or replace pen.
CHECK DIP SWITCH #4,5,6
Push pen completely onto pen arm.
Check to see that proper chart is
installed.
Check temperature range
See Calibration Procedure on p.8
or
return to factory for recalibration.
Check temperature range
Connect transducer to back of the
recorder (See diagram on pg. 3)
Model number of unit.
The problem you're experiencing with unit.
P222
P246
A015
N300