Technical Specification - Ega Master 79621 Manual De Instrucciones

Ventilador axial
Ocultar thumbs Ver también para 79621:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

REQUIREMENT – Observe the instruction
Ensure that the operation process is adhered to and avoid accidents and
expensive down times due to improper use of machines, devices and tools.
By using the mandatory sign you refer to the adherence of operation
instructions.
NOTICE – Gives recommendations and important hints for handling the
product.
IMPORTANT – Indicates application advice and other particularly useful
information.
REMARK:
In each case the symbol used does not replace the safety text. The text must always be read
fully. In some cases other symbols will be used with the signal words.
Nominal diameter
Operating pressure
Volume flow (unrestricted discharge)
Operating
pressure (bar)
2
3
4
Air consumption
Operating
Rotation (1/min
pressure (bar)
2
3
4
Air connection
Connecting line ID min.
Vibration* / Fan category
Noise pressure level LpA
Noise power level LwA
ATEX Classification
The performance data are guide values only, they depend basically on the application, the
operating pressure and the applied accessories.

TECHNICAL SPECIFICATION

Unit length
Rotation
79621
79622
Rotation
Rotation
(1/min ± 5%)
(1/min ± 5%)
1550
2050
2500
79622
79621
Rotation
± 5%)
(1/min ± 5%)
1550
2050
2500
Air quality
Weight
79621
500 mm
515 mm
max. 4 bar
max. 2500 1/min
1730
2.68 m³/s
2200
3.55 m³/s
2420
4.33 m³/s
1730
2.03 m³/min
2200
2.55 m³/min
2420
2.73 m³/min
Free of oil
Claw coupling ¾"
female
19 mm
46 kg
BV-3
105 dB (A)
119 dB (A)
II 2G c IIB T6
79622
600 mm
520 mm
max. 4 bar
max. 2420 1/min
2.75 m³/s
5.30 m³/s
5.83 m³/s
2.75 m³/min
3.50 m³/min
3.84 m³/min
Free of oil
Claw coupling ¾"
female
19 mm
58 kg
BV-3
99 dB (A)
109 dB (A)
II 2G c IIB T6