9.6_supp = 1
19.2_supp = 1
93.75_supp = 1
187.5_supp = 1
500_supp = 1
1.5M_supp = 1
3M_supp = 1
6M_supp = 1
12M_supp = 1
;
MaxTsdr_9.6 = 60
MaxTsdr_19.2 = 60
MaxTsdr_93.75 = 60
MaxTsdr_187.5 = 60
MaxTsdr_500 = 100
MaxTsdr_1.5M = 150
MaxTsdr_3M = 250
MaxTsdr_6M = 450
MaxTsdr_12M = 800
;
Redundancy = 0
Repeater_Ctrl_Sig = 2
24V_Pins = 0
Implementation_Type = "DPC31"
;
; Slave-Specification:
;
Freeze_Mode_supp = 1
Sync_Mode_supp = 1
Set_Slave_Add_Supp = 0
Auto_Baud_supp = 1
Min_Slave_Intervall = 10
Fail_Safe = 1
Max_Diag_Data_Len = 11
Modul_Offset = 0
Slave_Family = 6
Modular_Station = 1
Max_Module = 1
Max_Input_len = 4
Max_Output_len = 4
Max_Data_len = 8
;
; UserPrmData:
;
Max_User_Prm_Data_Len = 1
;
; Module Definition List:
;
Module = "PB340" 0xA3
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
Ext_User_Prm_Data_Ref(0) = 1
EndModule
;
Module = "PB306" 0x93
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
EndModule
;
Module= " PB541" 0xB3
Ext_Module_Prm_Data_Len = 1
Ext_User_Prm_Data_Const(0) = 0x00
Ext_User_Prm_Data_Ref(0) = 1
EndModule
;**************************************************************************
; Supported baudrates
; RTS-Signal (CNTR-P): TTL-level
; No 24V supply on Profibus-connector
; Freeze-Mode supported
; Sync-Mode supported
; Set_Slave_Address not supported
; Automatic baudrate recognition
; Fail-Save-Mode supported
; 5 byte user diagnostic data
; HMI unit
; Modular station with one module
; 32 bit input data (PB306/541)
; 32 bit output data (PB340/541)
; Max. 2 * 32 bit data (PB541)
; 1 byte user parameter data
; Config. PB340: 4 byte output data
; Config. PB306: 4 byte input data
; Config. PB541: 4 byte input data +
;
7