Install indoor unit
Connect the drain hose to the outlet pipe of the indoor unit.
1.
Bind the joint with rubber belt.
2.
Put the drain hose into insulating tube.
3.
Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain
slightly for smooth drainage of
Note: The insulating tube should be connected reliably with
the sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet in the water.
1.Open the surface panel.
2.Remove the wiring cover Fig.6.
3.Route the power connection cord from the back of the indoor unit and pull it toward the front
through the wiring hole for connection.
4.Connect the interconnection cord to the terminal block, and then fix the cord with cord anchorage.
5.Reassemble the clamp and wiring cover.
6.Recover the surface panel .
Install of Drain Hose
condensate.
Connect indoor and outdoor electric wires
Wiring cover
hose
downward
yellow-
brown
green
Outdoor unit connection
2 2
outlet pipe of
indoor unit
rubber belt
outlet pipe of
indoor unit
rubber belt
rubber belt
outlet pipe of
indoor unit
connected
bulge
Fig.6
outlet pipe of
indoor unit
drain hose
drain hose
insulating tube
insulating tube
distortion
Flooded