Sonel CMP-200F Manual De Uso página 58

Pinza amperométrica de mordaza abierta
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Low Z measurement
Range
6.000 V
60.00 V
600.0 V
All AC voltage ranges are specified from 5% to 100% of range
Input impedance: 3 kΩ
Frequency range: 50 Hz...1000 Hz (sine wave), 50/60 Hz (all
waves)
Overload protection: 600 V DC/AC RMS
Resistance measurement
Range
600.0 Ω
6.000 kΩ
60.00 kΩ
600.0 kΩ
6.000 MΩ
60.00 MΩ
Overload protection: 300 V DC/AC RMS
Capacitance measurement
Range
60.00 nF
600.0 nF
6.000 µF
60.00 µF
600.0 µF
4000 µF
Accuracy unspecified for capacitance of <6 nF
All capacitance ranges are specified from 10% to 100% of range
Overload protection: 300 V DC/AC RMS
56
Resolution
0.001 V
0.01 V
0.1 V
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Resolution
0.01 nF
0.1 nF
0.001 µF
0.01 µF
0.1 µF
1 µF
CMP-200F – USER MANUAL
Accuracy
 (3.0% m.v. + 40 digits)
Accuracy
 (1.0% m.v. + 4 digits)
 (1.5% m.v. + 4 digits)
 (2.5% m.v. + 4 digits)
 (3.5% m.v. + 4 digits)
Accuracy
 (3.0% m.v. + 5 digits)
 (3.5% m.v. + 10 digits)
 (5.0% m.v. + 10 digits)

Publicidad