Appendix:
1. Loads which can be controlled directly by the Load
Disconnect output of the BMS
Inverters:
All Phoenix inverters VE.Direct and Phoenix Inverters Smart:
Connect the LOAD DISCONNECT to the left-hand terminal (H) of the 2-pole
connector
DC-DC converters:
All Tr type DC-DC converters with remote on/off connector, and Orion 12/24-
20
Connect the LOAD DISCONNECT the right-hand terminal of the 2-pole
connector
Battery Protect and Smart Battery Protect
Connect the LOAD DISCONNECT to terminal 2.1 (right hand terminal) for the
Battery Protect and H pin for the Smart Battery Protet of the 2-pole connector
Cyrix -Li-Load
Connect the LOAD DISCONNECT to the control input
2. Loads for which an inverting remote on-off cable is
needed
(article number ASS030550100 or -120)
All Phoenix VE.Bus inverters and VE.Bus Inverter Compact rated at 1200VA
or more.
3. Solar charge controllers which can be controlled
directly by the Charge Disconnect output
BlueSolar MPPT 150/70 and 150/80 CAN-bus
Connect the CHARGE DISCONNECT to the left-hand terminal of the 2-pole
connector (B+)
SmartSolar MPPT 150/45 and higher, 250/60 and higher
Connect the CHARGE DISCONNECT to the right-hand terminal (marked +)
or the left-hand terminal (marked H) of the 2-pole connector
4. Solar charge controllers for which a VE.Direct non
inverting remote on-off cable is needed
(article number ASS030550320)
All BlueSolar MPPT models, except the BlueSolar MPPT 150/70 and 150/80
CAN-bus
SmartSolar MPPT up to 150/35