Safety Warnings - Poolaria PAR56 Manual De Instalación Y Mantenimiento

Proyector subacuático
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
• RGB models are operated using a remote control, which comes with the projector.
B
- Click the side selector to activate the remote control (A).
- Extend the antenna to ensure good signal coverage (B).
- Hold the remote control at least 2 meters from the projector.
A
It enables the following scenarios to be created: 1. Fade 1 / 2. Fade 2 / 3. Smooth / 4. Flash / 5.
Red / 6. Purple / 7. Green / 8. Cyan / 9. Blue / 10. White / 11. Orange / 12. Off.
It has a 12 V battery of 23 A.
In both cases, you should make sure that the voltage received by the lamp is never more than 12V AC.
6. MAINTENANCE:
To remove the floodlamp to the edge of the swimming pool loosen until the fastening dog yields sufficiently
so that the floodlamp unit can be separated from the housing.
To remove the lamp, unscrew the 6 screws which secure the decorative ring to the base of the floodlamp
(Fig.3).
Remove the lamp from the inside of the base of the floodlamp and disconnect the two terminals, loosening
the two screws which secure them to the lamp. (Fig. 4).
Change the lamp and assemble the Floodlamp, in the opposite order described in point 4 of assembly, taking
special care to:
• Connect the cable terminals to the lamp, using the 2 screws supplied with the lamp (Fig. 5).
• Fully centre the 110x11 O-ring in its seat.
• Firmly tighten the nuts.
Attention:
• Before any handling ensure that there is NO voltage supplied to the floodlamp.
• The new lamp should have the same characteristics as that supplied with the floodlamp PAR56.
• In order to ensure full watertightness, clean the seat of the O-ring for the lamp or replace the O-ring if you
observe any notches or permanent damage.
7. START-UP:
Ensure that the voltage the lamp receives is never greater than 12 V.
The floodlamp should only operate underwater while secured to the vertical walls of the pool. Never switch
on the floodlamp if it is not underwater.

8. SAFETY WARNINGS:

• If the cable or wiring of this luminaire becomes damaged, it may only be replaced by the manufacturer or
one of its service engineers, or a person with a similar qualification, in order to prevent any risks.
• The light source of this luminaire may only be replaced by the manufacturer, one of its service engineers
or a person with a similar qualification.
• The persons who are in charge of assembly should have the required qualificatlons for this type of work.
• Avoid making contact with the electric voltage.
• Comply with the current standards regarding accident prevention.
• In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL
WIRING. SWIMMING POOLS.
• Any operation related to the maintenance or replacement of parts should be performed with the floodlamp
disconnected from the electric power system.
• Do not handle with wet feet.
• The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any
electric components which have been inserted or handled at locations other than its own premises.
• This projector is resistant to pool treatments described below, always that the concentration values do not
exceed the following levels:
TYPE OF TREATMENT (concentration in water):
Chlorine (2mg/l), Bromine (5 mg/l), Salt electrolysis = Na Cl: (6 g/l).
Attention: Please note that the Ph of pool water always must be between 7.2 and 7.6.
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

7174171742

Tabla de contenido