Maintenance

6.1

Calibration / Adjustment

Only by an authorized Dräger Interlock service centre.
Check calibration at least every 12 months.
Once the service interval expires the display shows the message
Service due in X days.
If the unit is not serviced, the vehicle can nevertheless be
started during a transition period of several days (dependent on
the configured parameters).
6.2

Cleaning

To clean, wipe with a disposable tissue.
Do not submerge in liquid – liquid must not enter the sockets!
7

Disposal

Dispose of the product in accordance with the applicable rules and
regulations.
7.1

WEEE

This product must not be disposed of as municipal waste.
This is indicated by the adjacent icon.
You can return this product to Dräger free of charge. For
information please contact the national sales organisations
and Dräger.
Dräger Interlock 7000
8

Technical data

Measuring principle
Measuring range
Ambient conditions
For operation and storage -40 °C to 85 °C
Sensitivity drift
Display
Calibration interval
Dimensions (H x W x D)
Handset
Control unit
Weight
Interlock 5000 handset
Interlock 7000 handset
Control unit
Interlock 5000
Control unit
Interlock 7000
Voltage supply
Maintenance
Electrochemical DrägerSensor
Up to 3.0 mg/L
20 % to 98 % r. h.
600 to 1100 hPa
No influence of changes in altitude
on the measurement result
Typically 1 % of measured value /
month
Display
Typically 12 months
Approx. 138 mm x 61 mm x 36 mm
Approx. 148 mm x 90 mm x 32 mm
Approx. 180 g
Approx. 178 g
Approx. 195 g
Approx. 240 g
12 V to 24 V
33