ATTENTION: we recommend performing the above operations quickly and without hesitation,
avoiding, insofar as possible, the "center" points at which the valve on the male element
remains open and may admit air. We therefore recommend exerting as little pressure as
possible on the base of the cartridge and compressing it in order to obviate entry of air. Always
use protective gloves and goggles.
NOTE: while rotating the cartridge, compress slightly to release pressure.
NOTE: the cartridge may be removed whenever necessary; it is nevertheless preferable to
remove as infrequently as possible. The extracted cartridge retains its "collapsed" conformation
and is always ready for re-insertion.
NOTE: use only synthetic (polyester) oils or the oils recommended by the manufacturer.
Always refer to the information provided by the A/C system manufacturer
NOTE: Using tracers not recommended by the manufacturer will invalidate the warranty.
EMPTYING THE USED OIL CONTAINER
This operation must be performed whenever the oil level exceeds 200 cc. Procedure: remove
the container from its lodging very carefully and without exerting pressure on the scale.
Unscrew the container while holding the cap in place; empty the used oil into a suitable
container for used oils. Screw the container back on while holding the cap in place. Carefully
replace the container in its lodging without exerting pressure on the scale. N.B.: In order to
avoid damage to the oil scale, never exert pressure on it either from above or from below.
REPLACING THE PRINTER PAPER
Use only heat-sensitive paper of the type described below.
Paper width: 58 mm
Maximum paper roll diameter: 40mm
INSTRUCTIONS MANUAL
-36-