Models
LxWxH mm
355x355x740
Size of cut-out
330 x 330 mm
Net weight
Maximum load
Power
Amperage
Protection index
Models
Stack for all types of tableware
Capacity
LxWxH mm
Size of cut-out
Net weight
Maximum load

ELECTRICAL CONNECTION

y Tension 230V sigle phase 50/60Hz.
y Cable supplied with appliance, 1mm² section, 2 phase + earth.
y The appliances must be connected to a single phase, earthed supply and be hooked up to a high sensitivity differential line
conditioner, protected from surges.
Trolley :
y Connection to a 16 Amp. Single phase socket
y Before unplugging or plugging in the appliance, make sure that the master switch located on the control panel is off.
y The appliance cannot be connected without the single phase plug. Any modification will cancel the guarantee.
Fitted plate stack :
Model for plates :
y This appliance has no switch. The installer should connect it to a switch or an all pole circuit breaker.
y Heating devices are to be connected to an equipotential connection to be attached to screen M5 located at the bottom
(initials
).
USAGE
Stack other than versatile model 777406 :
y Adjust the distance of plate's stops by lifting them according to the diameter of the plates and by inserting the lower pin
into the chosen hole.
Can be adjusted for plates with diam. 200 to 310mm and diam. 200 to 260mm according to the model.
Multi-function stack 777406 :
y The stopper position/setting will vary according to whether you are using square/rectangular or round plates. Before putting
plates in, look inside the device, to the bottom of stack. Two of the four stoppers have two rows of positioning holes :
- Round plates : position the 2 stoppers in the rows that are on the O-shaped outline, representing a round plate. Drawing A
page 17.
- Square/rectangular plates : position the 2 stoppers in the rows that are
rectangular plate. Drawing B page 17.
General purpose stack :
y The number and the position of «crockery separation tubes» (item 20 of the spare parts list) are based on the dimensions
of the crockery placed in the stack. Adjuste springs according to the weight of plates :
For other values please make tests.
Each silo is equipped with round guide tubes (3 or 4 according to the model) around which the plate support is able to slide.
Remove the springs, beginning with those closest to the guides, always removing the same number per guide.
If possible, remove a spring around each guide. This method avoids unbalancing the system.
Stacks for round plates
Neutral
777432
777433
428x428x784
355x355x740
390 x 390 mm
330 x 330 mm
9 kg
13 kg
70 kg
80 kg
/
/
/
/
/
/
Stack for dishwasher baskets
777630
120/180 plates - 216 bolws
712x457x729
682 x 350 mm
19 kg
160 kg
Weight of plates
1100/1200 g
600/700 g
400/500 g
Heating
777431
777430
428x428x784
355x355x740
390 x 390 mm
390 x 390 mm
9 kg
13 kg
70 kg
80 kg
900 W
4 A
21
777830
7 dishwasher baskets
659x659x850
637 x 637 mm
13 kg
120 kg
-shaped outline, representing a square or
Nbre of springs stacks
12
9
6
Stacks for square plates
Neutral
777439
777434
428x428x740
330 x 330 mm
9 kg
13 kg
70 kg
80 kg
900 W
4 A
21
Stack for trays
777930
100/120 trays
673x578x722
635 x 495 mm
13 kg
120 kg
7

Publicidad