Sundstrom SR592 Instrucciones De Uso página 19

Ocultar thumbs Ver también para SR592:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
4. Face seal
5. Head harness
6. Sweatband, 5-pack
7. Comfortband
8. Welding filter, shade No. 8, SR 59008
Welding filter, shade No. 9, SR 59009
Welding filter, shade No. 10, SR 59010
Welding filter, shade No. 11, SR 59011
Welding filter, shade No. 12, SR 59012
Welding filter, shade No. 13, SR 59013
Welding filter, EN 3/10, SR 59005
Welding filter, EN 3/11, SR 59006
Welding filter, EN 4/5-13
Welding filter, 4/9-13, SR 59007
9. Outer protective lens
10. Inner protective lens for auto lens
Inner protective lens for R06-4508
11. Correction lens, dptr 1,0, SR 59014
Correction lens, dptr 1,5, SR 59015
Correction lens, dptr 2,0, SR 59016
Correction lens, dptr 2,5, SR 59017
12. Holder welding filter
13. Screw
14. Protective hood
15. Cleaning tissues SR 5226, box of 50
3. Use
3.1 Installation
See also the user instructions for fan unit SR 500/SR 700.
Welding filter
Fit a welding filter. See section 4.4.2 To change the
welding filter.
Breathing hose
Connect the breathing hose according to fig. 5.
3.2 Donning
Note that the equipment must always have supplied air
before putting on. See the user instructions for fan unit
SR 500/SR 700.
• Raise the visor and put the welding shield on. Fig. 6.
• If necessary, adjust the head harness, see fig. 7.
Height adjustment.
A - how high the welding shield sits on the head.
Angle adjustment between shield and head har-
ness.
B - the angle against the shield.
Space adjustment between shield and head har-
ness.
C - the space to the shield.
Width adjustment of the head harness.
D - adjustment of the width of the head harness.
• Lower the visor unit by pulling the face seal down under
your chin. Fig. 8.
• Insert a finger between your chin and the face seal and
run the finger along the contact surface of the face seal
all the way round to check that it fits well and comfortable
against the face, fig. 9. Adjust the comfort of the face
seal with the drawstring, fig 10.
The ears can be placed both inside or outside of the face
R06-4404
seal for optimal comfort.
R06-4403
• Check and adjust so that the breathing hose runs along
R06-4405
your back and that it is not twisted. Fig. 11.
R06-4510
T06-4001
3.3 Doffing
T06-4002
Do not take off the equipment until clear of the hazardous
T06-4003
area.
T06-4004
See also the user instructions for fan unit SR 500/SR 700.
T06-4005
4. Maintenance
T06-4006
T06-4007
The person who is responsible for cleaning and maintenance
T06-4008
of the equipment must have suitable training and be well
R06-4508
acquainted with work of this type.
T06-4009
4.1 Cleaning
R06-4008
Sundström cleaning tissues SR 5226 are recommended for
R06-4009
daily care.
R06-4509
If the equipment is more heavily fouled, the sweatband can
T06-4010
be washed with a mild soap solution.
T06-4011
If necessary, spray the welding shield with 70 % ethanol or
T06-4012
isopropanol solution for disinfection.
Wipe the plastic protective lens carefully, since they are
T06-4013
sensitive to scratching.
R06-4306
Automatic welding filters are very sensitive to moisture.
R06-4305
Use only a dry polishing cloth.
T06-4014
NOTE! Never use solvents for cleaning.
H09-0401
4.2 Storage
After cleaning, store the equipment in a dry and clean place
at room temperature. Avoid exposing it to direct sunlight.
4.3 Maintenance schedule
Recommended minimum requirements on maintenance
routines so you will be certain that the equipment will always
be in usable condition.
Visual inspection
Cleaning
Change of o-ring for
breathing hose
4.4 Change parts
Always use genuine Sundström parts. Do not modify the
equipment. The use of non-genuine parts or modification of
the equipment may reduce the protective function and put at
risk the approvals received by the product.
4.4.1 To change the outer protective lens
• Loosen the screw in the holder for the welding filter. Fig 12.
• Release and remove the holder for the welding filter. Fig 13.
• Release and remove the outer protective lens. Fig 14, 15.
• Fit the new outer protective lens. Fig. 16, 17.
• Fit the holder. Fig 13.
• Tighten the screw. Fig 18.
4.4.2 To change the welding filter
• Loosen the screw in the holder for the welding filter. Fig 12.
• Release the holder for the welding filter. Fig 13.
• Release and remove the the welding filter. Fig 19.
• Release and remove any inner protective lens. Fig 20.
• Fit any inner protective lens on the inside of the new welding
filter. Fig 21.
• Fit the new welding filter. Fig. 22.
• Fit the holder. Fig 13.
• Tighten the screw. Fig 18.
Before use
After use
Annually
19

Publicidad

Tabla de contenido
loading

Tabla de contenido