3. HOW TO INSTALL THE OUTDOOR UNIT

3-1. Transporting
When transporting the unit, have it delivered as close to the
installation site as possible without unpacking.
Use a hook for suspending the unit. (Fig. 3-1)
CAUTION
● When hoisting the outdoor unit, pass ropes or straps under
the bottom plate as shown in the figure above. When hoisting,
the angle between the rope and top panel must be 70° or
greater so that the rope does not come into contact with the
fan guard. (Use 2 lengths of rope 7.5 meters long or longer.)
● When passing the ropes through the square holes of the
bottom plate:
Place the rope in the outer edge of the square holes.
● Use protective panels or padding at all locations where the
rope contacts the outer casing or other parts to prevent
scratching. In particular, use protective material (such as
cloth or cardboard) to prevent the edges of the top panel from
being scratched.
● Be careful of the fan.
There is danger of injury if the fan starts to turn during
inspection. Be sure to turn OFF the remote power switch
before beginning inspection.

3-2. Installing the Outdoor Unit

(1) Use anchor bolts (M12) or similar to securely anchor the
unit in place. (Fig. 3-2)
Plate leg
Anchor bolts
Washer
(100)
The vibration insulator, base, or platform must be large enough
to bear the full surface of the base plate legs.
Fig. 3-1
Vibration insulator
50
Base
Unit: mm
Fig. 3-2
(2) Be sure the rubber vibration insulator and platform extend
to the inside of the legs. In addition, the washers used
to anchor the unit from the top must be larger than the
installation anchor holes. (Figs. 3-2 and 3-3)
4 – 15 × 20 hole
(B)
(C)
(A)
2870
(B)
890 (Ceiling panel dimensions)
(C)
790 (Installation hole pitch)
(B)
(C)
(A)
1880 (Ceiling panel dimensions)
(B)
890 (Ceiling panel dimensions)
(C)
790 (Installation hole pitch)
(Positions where anchor bolts are fastened)
Installation anchor hole (4 – 15 × 20 oval holes)
790 (Installation hole pitch)
890 (Ceiling panel dimensions)
24
(Detailed view of legs)
38.5
(A)
(B)
(B)
(C)
(C)
(D)
Top view
(D)
2770 (Installation hole pitch)
(E) 920 (Installation pitch)
(F)
950 (Maximum dimensions)
(A)
(B)
(C)
(D)
Top view
(D)
1780 (Installation hole pitch)
(E) 920 (Installation pitch)
(F)
950 (Maximum dimensions)
Unit: mm
Fig. 3-3
Unit: mm
Fig. 3-4

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Spw-c0905dzh8Spw-c1155dzh8Spw-c1305dzh8Spw-c1405dzh8

Tabla de contenido