5.
Application
PROTRONIC-T A3000 open non-touch, opto-electronically controlled washbasin
mixer DN 15 for connection to hot and cold water supplies. Design with temperature-
selector lever. With facility for externally controlling options such as fittings settings
and communication via ECC function controller. Adjustable flow duration, down to
the second.
Control functions:
– Hygiene flushing (10 seconds), 24 hours after last usage
– Safety switch-off when there is continuous reflection
Additional functions with ECC function controller (Ethernet):
– Automatic thermal disinfection according to DVGW work sheet W 551 as well
as safety switch-off
– Cleaning switch-off
6.
Technical Specifications
Minimum flow pressure:
Recommended flow
pressure:
Maximum operating
pressure:
Calculation flow rate:
Volumetric flow:
Operating voltage:
Operating voltage Solenoid
valve cartridge:
Power consumption:
Communication:
Type of protection:
1.0 bar
1–5 bar
10 bar
0.10 l/s for 3 bar flow pressure
24 V DC
12 V DC
2.5 W
Ethernet via ECC function controller
IP 68
info@hygiene-shop.eu - www.hygiene-shop.eu
0,07 l/s
0,07 l/s
5