Manual calibration

Pressing the CAL button (5) manually calibrates the device. This
allows measurements to be restarted and objects to be isolated
more precisely.
Maximum sensitivity is achieved when the device is held in the
air while calibrating.
!
The device and the wall must maintain contact during calibration (except
for calibration in mid-air) and throughout the entire measurement process.
A hand should remain at the device the entire time as well.
5
Select measurement mode
Briefly press the Mode button (4).
METAL-SCAN: Detecting metal in all non-metallic materials
AC-SCAN: Locating live lines directly under non-metallic cladding
6
Measuring in METAL-SCAN mode
The tool is able to detect hidden metal in all non-metallic materials,
e.g. brick, concrete, screed, wood, plaster fibreboard, gas concrete,
ceramic and mineral building materials.
– Select METAL-SCAN (button 4).
– As soon as the display switches from CAL
to CAL OK, you can move the device.
– MOVE: Move the tool slowly across the surface.
A
B
C
Tip 1: The position between the two markings is the mid-point of the metal object.
Through the high measuring sensitivity, thick metal objects appear broader than they are
in real life. Therefore move the device over the newly found object as shown in Image B.
The device is calibrated automatically during this process. Manual calibration should be
performed near the place found last as shown in Image C. Repeat this step as needed.
Manual
calibration
CombiFinder Plus
Isolate an object to be
measured by passing
over it several times.
07
GB