Calibration
8
The meter needs to be calibrated and tested on a regular basis to
ensure it produces accurate measurement results. We recommend
carrying out calibration once a year.
Technical data
Function
DC voltage
AC voltage
DC current
AC current
Resistance
Max. input voltage
Diode test
Continuity test
Open circuit voltage
Input resistance
Polarity
LCD
Fuse
Overvoltage
Pollution degree
Degree of protection
Max. rel. humidity
Operating temperature
Power supply
Dimensions
Weight (incl. batteries)
Test standards
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=mumepobo
MultiMeter-PocketBox
Range
200 mV
2/20/200 V
250 V
2/20/200 V
250 V
20 mA
200 mA
20 mA
200 mA
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
250 V AC/DC
open circuit voltage 1,5 V
Audible signal if the resistance is < 30 Ω
approx. 0.5 V (measuring voltage) for continuity
and resistance measurement (mode)
> 10 MΩ (V DC, V AC)
Sign for negative polarity
bis 1999 (3 1/2 segments)
250 mA/300 V, Ø 5 mm x 20 mm
CAT III - 300 V
2
IP 40
75% rH non-condensing
0 °C ... 40 °C
2 x LR44 1,5 V button cell
114 x 56 x 23 mm
101 g
EN 61326, EN 61010-1, EN 61010-2-031
Subject to technical alterations. 07.17
Accuracy
± (0,8% rdg ± 5 Digits)
± (1,0% rdg ± 5 Digits)
± (1,0% rdg ± 5 Digits)
± (1,2% rdg ± 5 Digits)
± (1,2% rdg ± 5 Digits)
± (1,5% rdg ± 5 Digits)
± (1,2% rdg ± 5 Digits)
± (1,0% rdg ± 5 Digits)
± (1,2% rdg ± 5 Digits)
± (1,5% rdg ± 5 Digits)
15
EN