Reference measurement:

Reference length
Set reference length
1a. Selection of
tens position
4. Rapid beeping: Measured value within reference value of ±1 mm.
Slow beeping: Reference value not yet reached.

Important notices

• The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
• The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
• In unfavourable conditions, e.g. with poorly reflecting surfaces, the
maximum deviation may be greater than 3 mm.
• Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
• Measurements made through glass (window panes) can falsify
measurement results.
• An energy-saving function switches the device off automatically.
• Clean with a soft cloth. Water may not be allowed to penetrate the
housing.
16
GB
1b. Number
set-up
reference
stop
1x
2. Define reference
value
3. Now move the laser
90°
forward and back.
1x