1 1 3 3 . . 4 4 . . 7 7 A A l l a a r r m m s s w w i i t t h h m m a a n n u u a a l l r r e e s s e e t t
The alarms with manual reset can be reset by pressing
than 5 seconds, if the causes are no longer present.
1 1 3 3 . . 4 4 . . 8 8 P P r r o o c c e e d d u u r r e e f f o o r r s s e e t t t t i i n n g g t t h h e e d d e e f f a a u u l l t t p p a a r r a a m m e e t t e e r r v v a a l l u u e e s s
Before to execute these operation contact the producer company)
To set the default parameter values for the controller, if 'Hdn'= 0, proceed as follows:
1) Switch the instrument off;
2) Switch the instrument on again, holding the
shown on the display;
N N o o t t e e : : the default values are set only for the visible parameters (e.g. C or F), according
to the model; see the table of "Operating parameters".
Vice-versa, if 'Hdn'<> 0, a number of sets of customised default parameters are availa-
ble. Proceed as follows:
1. Switch the instrument off.
2. Switch the instrument on again, holding the
yed.
3. Use the
sets between 0 and 'Hdn' can be chosen.
4. Pressing
N N o o t t e e s s : :
• The set of customisable default parameters can only be used on the controller if
there is suitable hardware (expanded EEPROM memory)
• If when loading a set of customised default parameters there is an EF EEPROM error
(memory error on the controller), the previous parameters can be restored by switching
the instrument off and on again.
• If there is an EF EEPROM error, to maintain the loaded parameters, enter parameter
configuration mode, check the values then save them to the EEPROM using the special
procedure. At then end of the operation, the EEPROM error signal will be cancelled.
• If there is a recurring EF EEPROM error when loading a set of customised default
parameters, the EEPROM on the instrument should be corrected using the program-
ming hardware key.
• After loading a set of customised default parameter, the controller automatically
updates the memory, saving both the levels of visibility and the values of the parame-
ters.
• The parameter 'Hdn' must have the same value in all the sets of customised default
parameters. For greater protection, parameter 'Hdn' must be set to not visible.
Code CT55900010
13/07/2006
and
buttons to select the desired set of default parameters. The
shows the message "Std" on the display.
English - 29
11.11
Pagina 29
and
together for more
button until the message "_std_" is
button until the value '0' is displa-
Rev. 03 - 07/'06