Volum
Description
WorkM
Operational mode Change with UP
and DOWN, confirm with PUSH.
Volum
Numerical parameter to set the
level of volume of the station audio
messages.
Only in case of number plate rec-
Plate
ognition! This parameter sets the
timeout for the number plate recog-
nition system. If no plate is detected
within this time the station does not
take it into consideration.
GateT
Tipologia e nome della stazione.
Per modificare premere UP e
DOWN, per confermare premere
PUSH.
1Barr
Parameter used to activate the "sin-
gle barrier" operational mode
By setting YES for this parameter,
entrance and exit use the same bar-
rier.
2Barr
Parameter used to activate the
"double barrier" mode. If = YES the
station controls 2 barriers: the first
normally open located before the
station and the second normally
closed. The first barrier closes when
the second enables transit. This
setup is used to avoid queues and
multiple entries / exits
MulBC
Parameter used to activate double
barcode operation. If the param-
eter = YES the station can detect 2
barcodes on the ticket (valid for exit
stations)
2TRMS
Parameter used to activate double
height operation. In this mode 2
stations of different height share
the same entrance / exit and there-
fore a single barrier. Set YES on both
stations
38 - Espas30 I
Values
NORMAL - operational entrance.
OPEN - open entrance.
CLOSED - closed entrance.
ON LOOP - open entrance.
(If the detection loop is activated)
SUBSCR.O. - season ticket holders'
entrance.
TICKET O. - ticket holders' en-
trance.
0...99
0...9 [sec]
IN1...IN3 = Entrance 1, 2 or 3
EXIT1...EXIT3 = Exit 1,2 or 3
COUNT1...COUNT3 = Kit
Capacity 1, 2 or 3
NO/YES (NO/YES)
NO/YES (NO/YES)
NO/YES (NO/YES)
NO/YES
Default
NORMAL
0
IN1
NO
NO
NO
NO