1. TECHNICAL FEATURES
Fire resistant – LFS 60P according to EN15659. 60 minutes fire protection for paper.
Power supply: 6 Volts (4 batteries, type AAA). Use only alkaline baterries. Look at the sell-by date on the batteries. Do not use
rechargable batteries.
Replace the batteries every year for correct functioning. Do not throw the batteries in the garbage.
Variable lenght codes, from 4 to 6 digits.
Automatic blocking system for 5 mintues when more than 3 consecutive incorrect codes are entered.
Low batteries warning system.
One user code plus one master code. The safe is delivered from the factory fitted with the master code 1-2-3-4-5-6. For your
security do not forget to change it.
Read carefully these instructions and warranty before any action.
2. FIRST USE
Fit four alkaline batteries type AAA as indicated on point 5 of this operating instruction.
Then open and close the safe several times (point 3)
Change the original master code and program your own user code (point 4)
IMPORTANT! Check all those points with the door open, before closing it.
3.
OPEING/CLOSING INSTRUCTIONS
To open the door:
Introduce the key (if your safe has one) and turn it to the right side until it stops.
Press button " * ". Enter master code or user code, consisting of 4 to 6 digits (master code factory setting: 1-2-3-4-5-6) and press
ENTER. Each correct keystroke is illuminated by a green LED and will be confirmed by an acoustic signal.
If the code entered was correct, the green LED will turn on and you will have 5 seconds to turn the knob or the handle clock-wise
and open the door.
To close the door:
Safes with knob: Close the door and turn the knob to the left.
Safes with handle: Close the safe door and turn the key to the left until it stops.
4.
PROGRAMMING OR CHANGING YOUR CODE
The change of the former code combination with a new one should be done while the safe door is open
A. Change of the master code: Every safe has been programmed with equal code. For your security do not forget to change it.
* Enter 1 Enter VALID MASTER (de fábrica 1 2 3 4 5 6) Enter NEW MASTER (4 a 6 dígitos) Enter NEW MASTER Enter
B. Change of the user code (usiing the master code)
* Enter 2 Enter VALID MASTER (de fábrica 1 2 3 4 5 6) Enter NEW USER (4 a 6 dígitos) Enter NEW USER Enter
C. Change of the user code (without using the master code)
Note: The change of the user code without using the master code is possible only if the user code was set in advance by using
master code.
* Enter 3 Enter VALID USER Enter NEW USER (4 a 6 dígitos) Enter NEW USER Enter
D. Deleting the user code only by using the master code
* Enter 0 Enter MASTER Enter . User code has been deleted
5. OTHER FEATURES
Incorrect code number: In case of entering an invalid code, an acoustic signal sounds 3 times and the red
LED flashes.
Blocking system: After three wrong entries, the keyboard is interlocked for 5 minutes. During the blocking
period, the red LED on the keyboard flashes in 5 seconds intervals (meanwhile it is impossible to open the
lock even if the valid code is entered).
Low batteries: If the voltage is low, every time a button * is pressed, and acoustic buzzer signal sounds 5
times and the red LED flashes. Such being the case, it is possible only lock opening and it is not permitted
to press ENTER for code change.
Replacement of batteries: The battery is placed in the low part of the keyboard body under the
removable cover. Replace the old battery with new one by observing the polarities. Use only 4 1,5 V-
Alkaline-Batteries Type AAA.
BTV S.L.- Ctra. Nacional II, Km 333; Pol. Ind. BTV-Alfindén; 50171 La Puebla de Alfindén (Zaragoza)
TEL. + 34 976 108 088 / TEL. SERVICIO ASISTENCIA TÉCNICA 902 190 386
www.btv.es; btv@btv.es
OPERATING INSTRUCTIONS. VULCANO SERIE
Cod. 140186. Rev.07/13