1. TECHNICAL FEATURES
•
Fire resistant – LFS 60P according to EN15659. 60 minutes fire protection for paper.
•
Power supply: 6 Volts (4 batteries, type AAA). Use only alkaline baterries. Look at the sell-by date on the batteries. Do not use
rechargable batteries.
•
Replace the batteries every year for correct functioning. Do not throw the batteries in the garbage.
•
Variable lenght codes, from 4 to 6 digits.
•
Automatic blocking system for 5 mintues when more than 3 consecutive incorrect codes are entered.
•
Low batteries warning system.
•
One user code plus one master code. The safe is delivered from the factory fitted with the master code 1-2-3-4-5-6. For your
security do not forget to change it.
Read carefully these instructions and warranty before any action.
2. FIRST USE
•
Fit four alkaline batteries type AAA as indicated on point 5 of this operating instruction.
•
Then open and close the safe several times (point 3)
•
Change the original master code and program your own user code (point 4)
IMPORTANT! Check all those points with the door open, before closing it.
3.
OPEING/CLOSING INSTRUCTIONS
To open the door:
Introduce the key (if your safe has one) and turn it to the right side until it stops.
Press button " * ". Enter master code or user code, consisting of 4 to 6 digits (master code factory setting: 1-2-3-4-5-6) and press
ENTER. Each correct keystroke is illuminated by a green LED and will be confirmed by an acoustic signal.
If the code entered was correct, the green LED will turn on and you will have 5 seconds to turn the knob or the handle clock-wise
and open the door.
To close the door:
Safes with knob: Close the door and turn the knob to the left.
Safes with handle: Close the safe door and turn the key to the left until it stops.
4.
PROGRAMMING OR CHANGING YOUR CODE
The change of the former code combination with a new one should be done while the safe door is open
A. Change of the master code: Every safe has been programmed with equal code. For your security do not forget to change it.
* Enter 1 Enter VALID MASTER (de fábrica 1 2 3 4 5 6) Enter NEW MASTER (4 a 6 dígitos) Enter NEW MASTER Enter
B. Change of the user code (usiing the master code)
* Enter 2 Enter VALID MASTER (de fábrica 1 2 3 4 5 6) Enter NEW USER (4 a 6 dígitos) Enter NEW USER Enter
C. Change of the user code (without using the master code)
Note: The change of the user code without using the master code is possible only if the user code was set in advance by using
master code.
* Enter 3 Enter VALID USER Enter NEW USER (4 a 6 dígitos) Enter NEW USER Enter
D. Deleting the user code only by using the master code
* Enter 0 Enter MASTER Enter . User code has been deleted
5. OTHER FEATURES
Incorrect code number: In case of entering an invalid code, an acoustic signal sounds 3 times and the red
LED flashes.
Blocking system: After three wrong entries, the keyboard is interlocked for 5 minutes. During the blocking
period, the red LED on the keyboard flashes in 5 seconds intervals (meanwhile it is impossible to open the
lock even if the valid code is entered).
Low batteries: If the voltage is low, every time a button * is pressed, and acoustic buzzer signal sounds 5
times and the red LED flashes. Such being the case, it is possible only lock opening and it is not permitted
to press ENTER for code change.
Replacement of batteries: The battery is placed in the low part of the keyboard body under the
removable cover. Replace the old battery with new one by observing the polarities. Use only 4 1,5 V-
Alkaline-Batteries Type AAA.
BTV S.L.- Ctra. Nacional II, Km 333; Pol. Ind. BTV-Alfindén; 50171 La Puebla de Alfindén (Zaragoza)
TEL. + 34 976 108 088 / TEL. SERVICIO ASISTENCIA TÉCNICA 902 190 386
www.btv.es; btv@btv.es
OPERATING INSTRUCTIONS. VULCANO SERIE
Cod. 140186. Rev.07/13