Descargar Imprimir esta página

Ecoflam E-BCU Diagnostic tool Manual De Uso página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Menus overview
• Burner stand-by,
waiting for heat
demend.
• Fan motor running,
igniter working,
prepurge time
displayed.
If a lock-out occours, the display shows alternatively the following messages.
• Burner lock-out.
• 1) Last lock-out cause
[-1].
• 2) State of the burner
when lock-out
occourred (flame signal,
supply voltage, running
time, burner starts
between last and
previous lock-out.
• 3) Second last lock-out
cause [-2].
• 4) State of the burner
when second last lock-out
occourred (flame signal,
supply voltage, running
time, burner starts
between second last and
third last lock-out.
420010145602
• Oil valve open, flame
stabilization time.
• Post-ignition.
• Service phone
number.
If a lock-out occours, to show the faut
cause push button BP1, the following infos
will be displayed:
BP1
• 5) Service phone
number.
• 6) Customer reference
number.
• Burner running, flame
on, flame signal level
displayed. Running time
displayed.
In order to reset the E-BCU, push the reset
button on the control box.
R: lock-out reset button +
led for lock-ot signal
www.ecoflam-burners.com
EN
5

Publicidad

loading

Este manual también es adecuado para:

3142931