Estado De Entradas - Carel μChiller Manual Del Usuario

Tabla de contenido

Publicidad

SPA
Index
Size
Ref.
69
1
P034
80
1
U078
7.2

Estado de entradas

Index
Size
Ref.
0
1
A01
1
1
A02
2
1
A03
3
1
A04
4
1
A05
5
1
A06
7
1
A08
8
1
A09
9
1
A10
10
1
A11
11
1
A12
12
1
A13
13
1
A14
14
1
A15
15
1
A16
16
1
A17
17
1
A18
18
1
A19
19
1
A20
20
1
A21
21
1
A22
22
1
A23
23
1
A24
24
1
A25
25
1
A26
26
1
A27
27
1
A28
29
1
A30
30
1
A31
31
1
A32
32
1
A33
33
1
A34
34
1
A35
35
1
A36
36
1
A37
37
1
A38
38
1
A39
39
1
A40
40
1
A41
41
1
A42
42
1
A43
43
1
A44
44
1
A45
45
1
A46
46
1
A47
47
1
A48
48
1
A49
49
1
A50
50
1
A51
51
1
A52
52
1
A53
53
1
A54
54
1
A55
55
1
A56
56
1
A57
57
1
A58
58
1
A59
59
1
A60
60
1
A61
62
1
A63
63
1
A64
64
1
A65
65
1
A66
66
1
A67
67
1
A68
68
1
A69
69
1
A70
70
1
A71
86
Type
Min/Max
R/W
UoM Description
BOOL
R/W
BOOL
R/W
Type
Min/Max
R/W
UoM Description
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
BOOL
R
P034 - Enable cranckcase heater (0=OFF, 1=ON)
U078 - Burst function enabling (0=Disabled, 1=Enabled)
Unit - Error in the number of retain memory writings
Unit - Error in retain memory writings
Unit - Remote alarm by digital input
Unit - Alarm remote set point out of range
Unit - Alarm user return water temperature probe broken or disconnected
Unit - Alarm user delivery water temperature probe broken or disconnected
Unit - User pump 1 overload
Unit - User pump 2 overload
Unit - Flow switch alarm, no flow present with user pump 1 active
Unit - Flow switch alarm, no flow present with user pump 2 active
Unit - User pumps group alarm
Unit - User 1 pump maintenance
Unit - User 2 pump maintenance
Unit - High chilled water temperature
Unit - Alarm source return water/air temperature probe broken or disconnected
Unit - Source 1 pump maintenance
Unit - Free-cooling anomaly
Circuit 1 - Alarm discharge pressure probe broken or disconnected
Circuit 1 - Alarm condensing temperature probe broken or disconnected
Circuit 1 - Alarm suction pressure probe broken or disconnected
Circuit 1 - Alarm evaporating temperature probe broken or disconnected
Circuit 1 - Alarm discharge temperature probe broken or disconnected
Circuit 1 - Alarm suction temperature probe broken or disconnected
Circuit 1 - High pressure alarm by pressure switch
Circuit 1 - High pressure alarm by transducer
Circuit 1 - Low pressure alarm by transducer
Circuit 1 - Alarm freeze evaporation temperature
Circuit 1 - Overload compressor 1
Circuit 1 - Overload compressor 2
Circuit 1 - Compressor 1 maintenance
Circuit 1 - Compressor 2 maintenance
Circuit 1 - Source fan 1 maintenance
Circuit 1 EVD - Low superheating (SH)
Circuit 1 EVD - Low evaporation pressure (LOP)
Circuit 1 EVD - Maximum evaporating pressure (MOP)
Circuit 1 EVD - Valve motor error
Circuit 1 EVD - Emergency closing
Circuit 1 EVD - Incomplete valve closing
Circuit 1 EVD - Offline
Circuit 1 Envelope - General alarm + Alarm zone
Circuit 1 BLDC - Delta pressure greater than the allowable at startup
Circuit 1 BLDC - Starting failure
Circuit 1 BLDC - Low differential pressure
Circuit 1 BLDC - High discharge gas temperature
Circuit 1 Inverter - Offline
Circuit 1 Inverter - General alarm + Error code
Unit - Circuit 2 board is offline
Unit - Error in the number of retain memory writings of Circuit 2 board
Unit - Error in retain memory writings of Circuit 2 board
Circuit 2 - Alarm discharge pressure probe broken or disconnected
Circuit 2 - Alarm condensing temperature probe broken or disconnected
Circuit 2 - Alarm suction pressure probe broken or disconnected
Circuit 2 - Alarm evaporating temperature probe broken or disconnected
Circuit 2 - Alarm discharge temperature probe broken or disconnected
Circuit 2 - Alarm suction temperature probe broken or disconnected
Circuit 2 - High pressure alarm by pressure switch
Circuit 2 - High pressure alarm by transducer
Circuit 2 - Low pressure alarm by transducer
Circuit 2 - Alarm freeze evaporation temperature
Circuit 2 - Overload compressor 1
Circuit 2 - Overload compressor 2
Circuit 2 - Compressor 1 maintenance
Circuit 2 - Compressor 2 maintenance
Circuit 2 - Source fan 1 maintenance
Circuit 2 EVD - Low superheating (SH)
Circuit 2 EVD - Low evaporation pressure (LOP)
Circuit 2 EVD - Maximum evaporating pressure (MOP)
Circuit 2 EVD - Valve motor error
Tab. 7.l