Registro De Entradas - Carel μChiller Manual Del Usuario

Tabla de contenido

Publicidad

7.4

Registro de entradas

Index
Size
Ref.
0
2
HuP1
2
2
HuP2
4
2
H1C1
6
2
H1C2
8
2
H2C1
10
2
H2C2
12
2
dSt1
14
2
Sct1
16
2
dSt2
18
2
Sct2
20
2
dSP1
22
2
ScP1
24
2
Cnd1
26
2
EuP1
28
2
dSP2
30
2
ScP2
32
2
Cnd2
34
2
EuP2
36
2
HSP1
38
1
C045
40
2
HFn1
42
2
HFn2
46
2
SEtA
48
2
SSH1
50
1
Opn1
51
2
SSH2
53
1
Opn2
54
2
rUSr
56
2
dUSr
65
2
67
2
71
1
90
2
rSPt
92
2
96
2
98
2
100
2
rps1
102
2
Mc1
104
2
MP1
106
2
Drt1
108
1
AlHs1_1
109
1
AlHs2_1
110
1
AlHs3_1
111
1
AlHs4_1
114
1
115
1
116
2
118
2
120
2
122
2
124
2
126
2
128
2
130
2
132
2
134
2
136
2
138
2
140
2
142
2
144
2
146
2
148
1
149
2
151
2
153
2
155
2
157
2
159
2
161
2
163
2
165
2
μchiller +0300053ES rel. 2.0 - 07.07.2020
Type
Min/Max
R/W
UoM
INT
R
h
INT
R
h
INT
R
h
INT
R
h
INT
R
h
INT
R
h
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
bar/psi dSP1 - Discharge press. probe of circ.1
REAL
R
bar/psi ScP1 - Suction press. of circ.1
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
bar/psi dSP2 - Discharge press. probe of circ.2
REAL
R
bar/psi ScP2 - Suction press. of circ.2
REAL
R
°C/°F
REAL
R
°C/°F
INT
R
h
INT
R
INT
R
h
INT
R
h
REAL
R
°C/°F
REAL
R
K/R
INT
R
%
REAL
R
K/R
INT
R
%
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
%
REAL
R
%
INT
R
REAL
R
°C/°F
REAL
R
%
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
rps
REAL
R
A
REAL
R
kW
REAL
R
°C/°F
INT
R
INT
R
INT
R
INT
R
INT
R
INT
R
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
INT
R
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
REAL
R
°C/°F
Description
HuP1 - User pump 1 working hours
HuP2 - User pump 2 working hours
H1C1 - Compr.1 circ.1 working hour
H1C2 - Compr.2 circ.1 working hour
H2C1 - Compr.1 circ.2 working hour
H2C2 - Compr.2 circ.2 working hour
dSt1 - Discharge temp. probe of circ.1
Sct1 - Suction temp. of circ.1
dSt2- Discharge temp. probe of circ.2
Sct2 - Suction temp. of circ.2
Cnd1 - Cond. temp. probe (or press. probe converted value) of circ.1
EuP1 - Evap. temp. probe (or press. probe converted value) of circ.1
Cnd2 - Cond. temp. probe (or press. probe converted value) of circ.2
EuP2 - Evap. temp. probe (or press. probe converted value) of circ.2
HSP1 - Source pump 1 working hours
C045 - Refrigerant type (3=R407C, 4=R410a, 6=R290, 10=R744, 22=R32)
HFn1 - Source fan 1 circ.1 working hour
HFn2 - Source fan 1 circ.2 working hour
SEtA - Actual setpoint used by thermoregulation
SSH1 - Suction Superheat of circ.1
Opn1 - EEV position of circ.1
SSH2 - Suction Superheat of circ.2
Opn2 - EEV position of circ.2
rUSr - Return water temp. from user
dUSr - Delivery water temperature to user
Fan1Req - Inverter request source fan circ.1
Fan2Req - Inverter request source fan circ.2
UnitStatus - Unit status (0=OFF by remote DI, 1=OFF by keyboard, 2=OFF by
scheduler, 3=OFF by BMS, 4=OFF by changeover mode Ch/HP, 5=OFF by alarm,
6=Unit in defrosting, 7=Unit ON, 8=Manual mode)
rSPt - Remote set point
PwrReq - Power request
SrcSetP_Circ1 - Source fan circ.1 set point
SrcSetP_Circ2 - Source fan circ.2 set point
PSD circuit 1:Actual rotor speed coming from inverter
PSD circuit 1: Current motor current [A]
PSD circuit 1: Current motor consumption [kW]
PSD circuit 1: Current drive temperature[°C]
PSD circuit 1: the last alarm log
PSD circuit 1:the last-but-1st alarm log
PSD circuit 1:the last-but-2nd alarm log
PSD circuit 1:the last-but-3rd alarm log
MotTyp - BLDC circ.1 Carel Database ID
Envelope zone circ.1
EnvPnt_X1 - Envelope point
EnvPnt_Y1 - Envelope point
EnvPnt_X2 - Envelope point
EnvPnt_Y2 - Envelope point
EnvPnt_X3 - Envelope point
EnvPnt_Y3 - Envelope point
EnvPnt_X4 - Envelope point
EnvPnt_Y4 - Envelope point
EnvPnt_X5 - Envelope point
EnvPnt_Y5 - Envelope point
EnvPnt_X6 - Envelope point
EnvPnt_Y6 - Envelope point
EnvPnt_X7 - Envelope point
EnvPnt_Y7 - Envelope point
EnvPnt_X8 - Envelope point
EnvPnt_Y8 - Envelope point
Envelope zone circ.2
EnvPnt2_X1 - Envelope point
EnvPnt2_Y1 - Envelope point
EnvPnt2_X2 - Envelope point
EnvPnt2_Y2 - Envelope point
EnvPnt2_X3 - Envelope point
EnvPnt2_Y3 - Envelope point
EnvPnt2_X4- Envelope point
EnvPnt2_Y4 - Envelope point
EnvPnt2_X5 - Envelope point