Twilight with IR sensor *:
Load A active at night (twilight detected by the panel) for a period of 5
minutes each time the IR sensor detects the passage of a person.
ON
Load B active only at night.
1 2 3 4 5 6
LoadA
LoadB
Lamp lit all night:
The lamp is active at night, from dusk (detected by the panel) until dawn.
The Load B output manages the energy saving of the lamp (See * time
diagram)
ON
WLight Flux
100%
1
2 3 4 5 6
70%
Twilight with 6h timer *:
ON
The lamp is active at night, from dusk (detected by the panel) for 6 hours.
The Load B output manages the energy saving of the lamp (See * time
1
2 3 4 5 6
diagram)
Twilight with 8h timer *:
ON
The lamp is active at night, from dusk (detected by the panel) for 8 hours.
The Load B output manages the energy saving of the lamp (See * time
1 2 3 4 5 6
diagram)
Twilight with 10h timer *:
ON
The lamp is active at night, from dusk (detected by the panel) for 10 hours.
The Load B output manages the energy saving of the lamp (See * time
1
2 3 4 5 6
diagram)
Twilight with 12h timer *:
ON
The lamp is active at night, from dusk (detected by the panel) for 12 hours.
The Load B output manages the energy saving of the lamp (See * time
1
2 3 4 5 6
diagram)
* time diagram
WLight Flux
100%
70%
Self-management with 12h timer:
The lamp is active at night, from dusk (detected by the panel) for 12 hours.
Load B manages the energy saving of the lamp (See * time diagram) by
automatically setting a few hours at full flow (H100% F) and others at
reduced flow (H70% F). The algorithm automatically calculates the number
of hours at 100% flow and the number of hours at 70% flow based on the
ON
energy available in the battery. If the IR sensor is connected, at the detection
of the person under the street lamp, the lamp flow will be set to 100% for 2
1 2 3 4 5 6
minutes.
on|off|off|on
WLight Flux
100%
70%
User manual
5 min
5 min
2 min
2 min
2 min
2 min
Timer
2 min
H100%F
H70%F
Timer 12h
SPC07-IP2
4
EN
Energy saving can be excluded by not
connecting the dimmer signal. In this
way, the lamp will remain on for the
entire duration of the timer at
maximum brightness (100% flux):
+LoadA
-LoadA
12V
WesternCO
GND
DIMMER
WLIGHT
BLUE
VERDE/GREEN
+LoadA
-LoadA
IR Sensor
PX01
ROSSO/RED
12V Aux Max 100mA
12V
WesternCO
GND
DIMMER
WLIGHT
Gnd
Sens
+LoadB
-LoadB
SPC07-IP
Gnd
Sens
+LoadB
-LoadB
SPC07-IP