2. Layout (Fig. 1-5)
1 Tank indicator
2 Tank cover
3 3 x 230 V~ socket-outlets
4 Earth connection
5 Safety tripping element 230 V
6 Voltmeter
7 Oil filler screw
8 Oil drainage screw
9 Oil shortage cut-out
10 On/Off switch
11 Choke lever
12 Reversing starter
13 Petrol cock
14 Wheels
15 Axle
16 Foot
17 Push bar holder
18 Push bar
19a Screws size M8x40
19b Screws size M8x25
20 Screws size M8x16
21 Washers for wheels
22 Securing split pins for wheels
23 Nuts size M8
24 Screwdriver
25 Spark plug wrench
26 Oil filler funnel

3. Proper use

The device is designed for applications operated with
a 230 V~ / 400 V ~ alternating current source. Be
sure to observe the restrictions in the safety
instructions. The generator is intended to provide
electric tools and light sources with electricity.
When using the device with household appliances,
please check their suitability in accordance with the
relevant manufacturer's instructions. In case of
doubt, ask an authorized dealer of the respective
appliance.
The machine is to be used only for its prescribed
purpose. Any other use is deemed to be a case of
misuse. The user / operator and not the
manufacturer will be liable for any damage or injuries
of any kind caused as a result of this.
Please note that our equipment has not been
designed for use in commercial, trade or industrial
applications. Our warranty will be voided if the
machine is used in commercial, trade or industrial
businesses or for equivalent purposes.

4. Technical data

Generator
Protection type:
Continuous rated power P
(S1):
rated
Maximum power P
(S2 2 min):
max
Rated voltage U
:
rated
Rated current I
:
rated
Frequency F
:
rated
Drive engine design:
Displacement:
Max. power:
Fuel:
normal unleaded petrol
Tank capacity:
Engine oil:
Consumption at 2/3 load:
Weight:
Sound pressure level L
:
pA
Sound power level L
:
K uncertainty
WA
Power factor cos ϕ:
Power class:
Temperature min.:
Max. temperature:
Max. altitude (above mean sea level):
Spark plug:
Operating mode S1 (continuous operation)
The machine can be continuously operated with the
quoted power output.
GB
Synchronous
IP23M
5000 W/230 V~
5500 W/230 V~
3 x 230 V~
20 A (230V~)
50 Hz
4-stroke, air-cooled
389 cm³
7 kW / 9.5 hp
25 l
ca. 1,1 (15W40)
approx. 1.8 l/h
75,95 kg
74,5 dB(A)
96 dB (A)/1,89 dB(A)
1
G1
-10°C
40°C
1000 m
F7RTC