4. Installing or Replacing a Lamp
Turn the plastic ball counterclockwise gently while holding the ring between the base and the ball. Remove the old
lamp and insert a new one, screwing it clockwise to fix it. Only install the lamp when the device is unplugged from the
mains. Replace the lamp if it is damaged but take care to let the lamp cool down before you do this.
Do not install lamps with a higher wattage than that for which the device was designed. Use two 240V/15W lamps,
E15 socket.
5. Installation / Operation
CAUTION: Make sure there are no inflammables within a radius of 50cm when you are mounting the device.
Connect the device to the mains.
Put the ON/OFF button in the ON-position. The device starts rotating at a steady pace. Put the ON/OFF button in the
OFF-position to deactivate the device.
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, mounting supports and connections should not be modified or tampered with e.g. do not drill extra
holes in mounting supports, do not change the location of the connections...
3. The electric power supply cables should be undamaged. Have this device installed by a qualified technician.
4. The moving parts must show no traces of wear and tear and should be well-balanced.
5. Disconnect the device from the mains before cleaning it.
6. Wipe the device clean regularly using a moist and clean cloth. Do not use alcohol or solvents on the device.
7. The user should only replace a lamp when necessary (see also 4. Installing or Replacing the Lamp). Actual
repairs should always be handled by a qualified technician. Order any spare parts with your local dealer.
7. Technical Specifications
Power Supply
Power Consumption
Dimensions
Total Weight
Lamp
Max. Ambient Temperature
The information in this manual is subject to change without prior notice.
VDL4DL2_v2
240Vac / 50Hz
30W max.
340 x 140 x 200mm
1,4kg
2 x 240V / 15W, E15 socket (Velleman order code LAMP4DL2)
45°C
- 4 -