Cognex In-Sight CIO-MICRO Manual De Instrucciones página 5

Ocultar thumbs Ver también para In-Sight CIO-MICRO:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
Precautions
Observe these precautions when installing the I/O module to reduce the risk of injury
or equipment damage:
Power for the I/O module is intended to be supplied by a NRTL listed power
l
supply with a 24VDC output rated at 750mA or more, a maximum short
circuit current rating of less than 8A, a maximum power rating of less than
100VA, and marked Class 2 or Limited Power source (LPS). Any other
voltage creates a risk of fire or shock and can damage the components.
Applicable national and local wiring standards and rules must be followed.
Never connect the I/O module to a power source other than 24VDC. Any
l
other voltage creates a risk of fire or shock and can damage the hardware.
Do not connect the 24VDC power source to any terminals other than the
24VDC + and – power terminals.
The shield ground connections of the RS-232 port, LAN port, PoE port, I/O
l
port and Frame Ground terminal are internally connected. The system
grounding is designed to be at a zero ground potential; this zero ground
potential extends through the cable and to peripheral equipment (e.g. a
vision system, PLC, etc.). To ensure safe operating conditions, it is strongly
recommended that all ground connections are checked to ensure that a
zero ground potential is met.
The I/O module must be grounded by attaching the I/O module's Frame
l
Ground terminal to a frame ground.
The I/O module is intended for indoor use only.
l
Do not install the I/O module where it is directly exposed to environmental
l
hazards such as excessive heat, dust, moisture, humidity, impact, vibration,
corrosive substances, flammable substances, or static electricity without a
protective enclosure.
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

In-sight cio-micro-cc i/o

Tabla de contenido