of the LED signal lights flash. Once the photocells are running
correctly again, the control unit is ready for normal operation.
This ensures monitoring against failures, in compliance with EN
954-1, Category 2.
Control input test:
On each low voltage control input, the control unit uses a LED
signal to make the status readily known.
Operating logic: when a LED is on it means the input is closed,
when a LED is off it means the input is open.
LED MANAGEMENT :
After 3 minutes of inactivity in the programming procedure,
there is the automatic shutdown of
the Leds
for energy
savings. A single press of the SEL or SET key, or a movement
command will activate the LED light up according to settings
programmed previously.