4. Operation of the spiral mixer by means of the
touch digital panel
4.1
Description
4.1.1
Timers
The timers are located at the upper side of the panel. Timer I is for
reverse direction, timer II for first speed, timer III for second speed.
The timers are set by means of the
+
once, the set time will increase by 10 seconds. The maximum time
that can be set is 20 minutes. After 20 minutes, the timer will start from
0 minutes again.
Press the
When the spiral mixer is switched ON , the timers will indicate the set
time. When the timer starts to work, the time indicated on the timer will
be reduced 10 seconds at a time until it reaches 0.
When the safety cover is raised during AUTOMATIC operation, the
timer will stop at the current position. When the spiral mixer restarts
after such a stop, the timer will continue from the current position to
finish the remaining time.
During MANUAL operation, the timer will
not work.
When the OFF -key is pressed, the timers
will return to the set time.
6
-
key for reducing the set time by 10 seconds.
+
-
and
-keys. If you press the
Safety cover open