Installation option 5, circuit diagram: Four doors with a reader/electric strike and a controller each (including
add-on module)
* When connecting several readers to an RS 485 interface
on the WTC 200, the readers must have different addresses.
Please observe the technical instructions on "Einstellung der
Adresse bei DIALOCK Leseköpfen" [Setting addresses for
DIALOCK reader heads] in this regard.
LAN Cat.5
230V NYM 3X1,5²
L N
230 VAC
12 VDC
-
+
NC
+
NC
NC
-
NC
B
NC
A
NC
NC
NC
Adr. 1*
WRU 200
1
NC
NC
+
NC
-
NC
B
NC
A
NC
NC
NC
Adr. 1*
WRU 200
2
Fig. 47c: Installation option 5, circuit diagram
*For this installation option, the "WTX 200 I/O board" add-on module also has to beinstalled (See chapter "5.4
Mounting the WTX 200 I/O board add-on module" on page 83).
118
WTC 200
WTX 200
- +
- +
WTX200 jumper
P13 P12
P11 P10
P9
P8
P7
P6
P5
P4
P3
P2
P1
NC
+
NC
-
NC
B
NC
A
NC
NC
NC
NC
Adr. 2*
WRU 200
3
NC
+
NC
-
NC
B
NC
A
NC
NC
NC
NC
Adr. 2*
WRU 200
4
Terminal Functionality
1 NO 1
2 COM 1
3 NO 2
4 COM 2
5 IN 4
6 GND
- +
- +