Descargar Imprimir esta página

Danfoss OPTYMA SLIM PACK OP-LSHM Manual De Instructiones página 8

Ocultar thumbs Ver también para OPTYMA SLIM PACK OP-LSHM:

Publicidad

Instructions
Code E : OP-lSHM048 - 068 - 067 - 084 - 098, OP-MSUM034 - 046 - 057 - 068 - 080 - 093 - 108
0
1
1
3
-F1
2
4
L1 L2
380-400V3N~/50Hz
Code G : OP-lSHM048 - 068
0
1
-K1
DATE
23.11.12
DRW
u249499
u249499
a
add models
06.02.14
RH
APPR
APP
REV
DATE
NAME
NORM
DIN61346
-F2
xxA
-F1
-K2
-X1
L
N
230V1N~/50Hz
Legend/Legende/légende
BK
black/schwarz/noir
BU
blue/blau/bleu
BN
brown/braun/marron
GY
grey/grey/gris
RD
red/rot/rouge
WH
white/weiss/blanc
DATE
DRW
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This
APPR
A
model
06.02.14
RH
also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trade-
APP
REV
DATE
NAME
NORM
marks in this material are property of the respective companies. Performer
FRCC.EI.026.A3.02 - February 2014
2
3
1
1
3
5
-K1
-F3
3A
2
4
6
2
1
3
5
95
97
-F2
98
xxA
2
4
6
96
5
7
6
8
N1
N2
M
-M1
3~
-X1
PE
L3 N
PE
2
3
1
1
3
5
wiring diagram/Schaltplan/plan de circuits
-F3
OP-MSUM034MLW05E
(114X7062)
3A
2
4
6
2
OP-MSUM046MLW05E
(114X7064)
OP-MSUM057MLW05E
(114X7066)
OP-MSUM068MLW05E
(114X7068)
OP-MSUM080MLW05E
(114X7070)
1
3
5
95
OP-MSUM093MLW05E
(114X7071)
97
OP-MSUM108MLW05E
(114X7072)
98
2
4
6
96
-C1 -R1
N1
N2
-C2
5
5
1
-R2
2
S
C
R
M
-M1
1~
PE
PE
PE
Legend
A1
Voltage relay
B1*
Fan speed controller (option)
B2
High and Low pressure switch
E1
Crankcase heater
M1
Compressor
M2
Fan motor
S1*
Room thermostat (option)
17.12.13
wiring diagram/Schaltplan/plan de circuits
u249499
OP-LSHM048NTW05G
u249499
OP-LSHM068NTW05G
DIN61346
4
5
-A1
L1
SM500
L2
L3
MG73BF
P
N
16 18 15
26 28 25
21
-K1
22
1
2
3
-C1
1
M
-E1
-M2
1~
2
-X1
PE
4
5
-A1
L1
SM500
L2
L3
MG73BF
OP-LSHM048NTW05E
(114X7088)
P
OP-LSHM068NTW05E
(114X7090)
N
OP-LSHM067LLW05E
(114X7091)
OP-LSHM084LLW05E
(114X7092)
21
OP-LSHM098LLW05E
(114X7075)
-K1
16 18 15
26 28 25
22
1
2
3
-C3
1
M
-E1
-M2
1~
2
-X1
PE
(114X7087)
(114X7089)
, Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
®
6
7
-F2
OP-MSUM034MLW05E
7,0A
OP-MSUM046MLW05E
9,5A
OP-MSUM057MLW05E
OP-MSUM068MLW05E
OP-MSUM080MLW05E
OP-MSUM093MLW05E
OP-MSUM108MLW05E
OP-LSHM048NTW05E
4,8A
OP-LSHM068NTW05E
8,4A
OP-LSHM067LLW05E
OP-LSHM084LLW05E
OP-LSHM098LLW05E
-K1
A1
4
5
6
7
A2
-B2
-B1*
A
2
P<
B
P
P>
PE
1
D
PE
C
-S1*
-X1
PE
6
7
-F2
OP-LSHM048NTW05G
OP-LSHM068NTW05G
DEPT.
DRAWING-NO.
CC-RCU
-K1
A1
4
A2
5
6
7
-B2
-B1*
A
2
P<
B
P
P>
PE
1
D
PE
C
-S1*
-X1
PE
DEPT.
DRAWING-NO.
CC-RCU
Copyright Danfoss Commercial Compressors - DSS - 02/14
8
9
10A
13A
15A
15A
16A
12A
15A
15A
8
8
9
11A
17A
=
+
SHEET
1
118R0113
OF
1
8
=
+
SHEET
1
118R0144
OF
1

Publicidad

loading

Este manual también es adecuado para:

Optyma slim pack op-msumOptyma slim pack op-mshm