3.

Erection

3.1 Place of Installation

The TankQuick may only be used at sites such as petrol stations or workshops that
have been properly set-up for such work. The place of installation must be chosen in
such a way as neither to present danger to persons nor to pollute the environment.
The following points must be observed:
The device must be used in such a way that any spilt fuel is trapped, is noticed,
and can be collected. It must therefore only be used and stored on a liquid-tight
floor. Spilt drops must be collected immediately.
In accordance with TRBS 3151, the area with a radius of approx. 0.2 m around
the equipment is to be classified as Ex-zone 2. The necessary explosive hazard
protection measures must be taken. The device must therefore only be used in
the open air or in well-ventilated rooms.
Smoking and naked flames, in particular, are forbidden close to the device.
When not in use it must only be stored in rooms where people doesn't stay. En-
sure good ventilation and that the temperature of the device will not rise.
In order to disperse any static electric charge, the unit must not be placed on in-
sulating surfaces.
The place of installation must provide adequate protection against unauthorised
use.
It must be kept where it is protected from damage by third parties, e.g. not
close to the path of vehicles or working areas.
Keep it where it is protected from becoming heated (e.g. by direct exposure to
sunlight).

3.2 Compressed Air Supply

Fault-free operation involving relatively little servicing is only ensured if the supply
of compressed air is free from dirt, water condensation and oil.
The use of a compressed air filter with an automatic condensate drain by the user is
to be greatly recommended.
An input pressure of at least 7 bar is required to operate the TankQuick.
4.
Commissioning

4.1 Specifying the Liquid

Liquid residues will be found even when the container has been emptied. In order to
ensure that there is no mixing of sorts, the medium for a device must be specified
during commissioning (diesel, petrol or E85).

4.1 Adjusting the Operating Pressure

When first preparing the device for use, and when the operating pressure of the com-
pressed air supply changes, the internal operating pressure of the feed pump must be
checked, and may require adjustment. The internal operating pressure can be read
from the manometer when the compressed air supply is connected.
22