Hansgrohe Mediano 14261000 Modo De Empleo página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
Operation (see page 26)
Dimensions (see page 24)
Flow diagram (see page 24)
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice versa,
when mixer is closed
Spout temperature does not cor-
respond with temperature set
Temperature regulation not possible
Shower or spout dripping
Instantaneous heater didn't work with
thermostat
English
Cause
- Supply pressure inadequate
- Filters are dirty (#96922000)
- Shower filter seal dirty
- Backflow preventers dirty or leaking - Clean backflow preventers, ex-
- Thermostat has not been adjusted
- Hot water temperature too low
- thermo cartridge calcified
- Dirt or sedimentation on valve seat,
shut-off unit damaged
- Ecostop safety set removed.
(#95042000)
- Flow limiter in handshower isn't
removed
- Filters are dirty
- check valve hasn't moved back
Assembly see page 18
Spare parts (see page 25)
Cleaning
see enclosed brochure
Test certificate (see page 28)
Remedy
- Check water pressure (If a pump
has been installed check to see if
the pump is working).
- Clean filter in front of the mixer
and on the MTC-thermo cartridge
(#96922000)
- Clean filter seal between shower
and hose
change if necessary
- Adjust thermostat
- Increase hot water temperature to
42 ºC to 65 ºC
- Exchange thermo cartridge
- Clean or exchange shut-off unit
- Ecostop Remove Ecostop safety set
(#95042000)
- Remove flow limiter
- Clean the filter / exchange filter
- Exchange check valves
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mediano 14241000

Tabla de contenido