Installation; Site; Electrical Connection; Voltage - Kripsol KNG Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10

4. INSTALLATION

4.1 SITE

ATTENTION
Only qualified personnel should install and connect the unit.
The unit must be installed in a dry site. The site must be equipped with a drainage point in
the floor to protect against flooding. If the unit is installed in a humid site, a ventilation system
must be installed to prevent the formation for condensation. In cases where the unit is installed
in confined areas, a forced ventilation system may be required to ensure that the ambient
temperature of 40 ºC (104ºF) is not exceeded.
Do not store pool chemicals near to the unit.
It is important to leave sufficient clearance to allow for the horizontal removal of the motor block
and the vertical removal of the hair filter (see drawing in
4.2 INSTALLATION
The unit must be installed away from corrosive or flammable liquids.
It must be anchored to the floor using two M8 bolts or draw bolts of size 8 diameter and of
sufficient length to ensure a secure fixture.
The unit must installed as close to the pool as possible and preferably at an elevation of 0.5
meters below sea level (never more than 3 m) to enable "charged" operation.
The pipes used for the installation must be principally PVC.
The intake pipe must be completely watertight and installed with a downward slope of no less
than 1/100, thus preventing the formation of air pockets.
At permanent installations, where the pump is located above the water level (suction
installations), the intake pipe must be equipped with a foot valve and every effort must be made
to ensure that the majority of the pipe is located below the level of the pump intake shaft until
reaching the point that vertically coincides with the shaft. The intake pipe must be a rigid pipe.
At permanent installations where the pump is located below the water level, a stop valve should
be installed at both the intake and the discharge.

5. ELECTRICAL CONNECTION

The electrical installation must fully comply with the Regulations and Supplementary
Technical Provisions in force in each country and must be carried out by an
DIN Standard
authorised installer.
4844-W8
DIN Standard
4844-W8

5.1 VOLTAGE

The supply voltage to the motor must match the voltage indicated on the unit's rating plate, with
a permitted variation of + 10%. If the supply voltage is less than 90% or greater than 110% of
the voltage indicated on the rating plate, contact the power supply company.
Do not connect a three-phase motor to a single-phase power supply or vice-versa.
Dangerous voltage may cause shock, burns or even death.
Connect to ground before connecting the power. The power
supply must be equipped with neutral and earth conductors.
25
FIGURE 1).

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Kng075bKng100bKng150bKng200b

Tabla de contenido