lavatory, since they could damage the discharge and filling mechanism materials with a result of
escapes, by starting continuously the system.
- Along with these documents, it is provided an adhesive label to be placed on a percep-
tible place (we recommend to place it inside the lavatory lid) as a warning sign to
avoid foreign wastes.
- Please, do not use the lavatory nor any of the sanitary appliances connected
to the waste disposer when, under any circumstances, there is a power cut.
- In areas with a frost risk due to low temperatures, it is recommended to
protect pipes with thermal insulators, as well as to prepare the whole system
(cistern, waste disposer and evacuation pipes).
- You may prevent freezing by following these steps:
- Close the stopcock feeding the cistern and discharge it.
- Fill in the cistern with antifreeze solution suitable for plumbing.
- Discharge the cistern again. The antifreeze solution will go through the installation and will fill the
evacuation pipe.
- This warranty does not cover the damages caused in the waste disposer due to freezing.
7. MAINTENANCE OPERATIONS.
Jimten waste disposer has been designed to fulfil high reliability and years of working, hereby please
find detailed the most common maintenance operations, as well as a quick troubleshooting guide for
problems you may easily solve.
7.1. CLEANING.
In order to clean the lavatory connected to the waste disposer, it is recommended to use any market
high-quality cleaner with no acid components.
In areas with a high level of water hardness and for the purpose of eliminating the lime deposits, it is
recommended to clean regularly the appliance as follows:
- Disconnect the waste disposer from the electrical current.
- Pour into the lavatory a mixture of roughly 1 litre of vinegar and 3 litres of water.
- Leave the mixture to work for some hours.
- Connect the waste disposer again and start it.
7.2. TROUBLESHOOTING GUIDE.
Before performing any operation, please verify the following steps:
- Check that the filling and discharge mechanisms of the lavatory cistern are in good condition, and the
water supply to the cistern remains open.
- Check that the waste disposer in connected to its socket for a proper working, and check it is work-
ing (by checking that the differential has not tripped and the magneto thermal circuit breaker remains
connected)
- Please check the waste disposer thermal disconnection system has not been set in motion (the waste
disposer includes an automatic disconnection system in case of extremely high temperatures), by
waiting roughly 20 minutes (may vary depending on temperature conditions). In case of a excessively
long operating, or if the waste disposer is started continuously, please check if there is any sort of
leaking from the cistern to the lavatory or in the rest of the connected appliances.
You must also check that there is no return to the waste disposer through the non-return valve of the
evacuation pipe due to an inappropriate closing thereof (verify that the clappet fits properly). (see
replacement-cleaning of the non-return valve on page 24).
T-604 CS WASTE DISPOSER
INSTRUCTIONS AND MAINTENANCE GUIDE - 21